Possible Causes
- Fuse(s)
- SJB
- Accessory delay relay
DELAYED ACCESSORY RELAY INOPERATIVE/DOES NOT OPERATE CORRECTLY PINPOINT TEST REFERENCE
| PINPOINT TEST 5 | THE DELAYED ACCESSORY RELAY IS INOPERATIVE/DOES NOT OPERATE CORRECTLY | ||
|---|---|---|---|
| STEP | INSPECTION | ACTION | |
| 1 | CHECK ACCESSORY DELAY RELAY SUPPLY VOLTAGE
|
Yes | Go to next step. |
| No | Verify smart junction box (SJB) fuses 6 (10A) and 16 (30A) are OK. If the fuses are OK, install a new SJB. See SMART JUNCTION BOX (SJB) . Test the system for normal operation. | ||
| 2 | CHECK ACCESSORY DELAY RELAY COIL VOLTAGE
|
Yes | Go to next step. |
| No | Install a new SJB. See SMART JUNCTION BOX (SJB) . Test the system for normal operation. | ||
| 3 | CHECK ACCESSORY DELAY RELAY COIL GROUND CIRCUIT (B) FOR AN OPEN
|
Yes | install a new accessory delay relay. Test the system for normal operation. |
| No | Install a new SJB. See SMART JUNCTION BOX (SJB) . Test the system for normal operation. | ||