Home >> Mazda >> 2006 >> MX-5 Miata Base >> Repair and Diagnosis >> Body & Frame >> Door Locks >> Security System And Locks System (Advanced Keyless System) >> Immobilizer System Component Replacement/Key Addition And Clearing [With Advanced Keyless System] >> No. 2 Key Additional Programming Procedure (Using the WDS or Equivalent) >> Procedure
April 5, 2026: LEMON Manuals is launched! Read the announcement.

No. 2 Key Additional Programming Procedure (Using the WDS or Equivalent): Procedure

  1. Prepare key 1 for programming.
  2. Start the engine using a valid key or card key.
    CAUTION:
    • Do not place the card key in the vehicle when starting the engine with the valid key, otherwise programming cannot be performed. If the engine is started with the card key, remove the card key from the vehicle after the engine is started.
  3. Verify that the security light illuminates for approx. 3 s  , and then goes out.
  4. Turn the ignition switch to the LOCK position.
  5. Connect the WDS or equivalent to the DLC-2. (See WDS OR EQUIVALENT CONNECTING PROCEDURE  .)
  6. Using key 1, turn the ignition switch to the ON position.
    NOTE:
    • Although the security light flashes and DTC 15 is displayed, this does not indicate an improper procedure. Continue to perform the procedure as indicated.
  7. Select "BODY/SECURITY/PATS (immobilizer) function" from the WDS or equivalent screen menu.
  8. Select "Ignition key additional programming" from the WDS or equivalent screen menu.
    NOTE:
    • After selecting the above menu, "operation is successful" is displayed. At this point, the key that turned the ignition switch to the ON position is completely programmed.
    • In this procedure, the necessary number of the keys are completely programmed. To finish the additional key programming, go to Step  13.
    • If additional keys need to be programmed, go to the next step.
  9. Perform the security access according to the directions on the WDS or equivalent screen. (See SECURITY ACCESS PROCEDURE  .)
  10. After verifying that the PATS function menu is displayed again on the WDS or equivalent screen, turn the ignition switch to the LOCK position and remove key 1.
  11. Using the key to be programmed, turn the ignition switch to the ON position.
  12. Return to the Step  6.
  13. After verifying that the PATS function menu is displayed again on the WDS or equivalent screen, select the "Finish (this menu)" to finish the WDS or equivalent procedure.
  14. After Step  10, wait 5 s or more  , and then turn the ignition switch to the LOCK position.