No.5 Resetting Procedure for the Immobilizer System when Replacing the PCM or Instrument Cluster Conditions: Procedure
Courtesy of MAZDA MOTORS CORP.
- Have two or more keys (key 1, key 2) ready for registration.
- Using key 1, turn the ignition switch to the ON position.
NOTE:
- When replacing only the PCM: The security light illuminates for 3 s
and then goes out.
- When replacing the instrument cluster: Although the security light flashes and DTC 15 is displayed, this does not indicate an improper procedure. Continue to perform the procedure as indicated.
- Connect the WDS or equivalent to the DLC-2.
- Select "Body/Security/PATS function" from the WDS or equivalent screen menu.
- Perform security access as indicated on the WDS or equivalent screen. (See NO.6 SECURITY ACCESS PROCEDURE
.)
- Select "Parameter Reset" from the WDS or equivalent screen menu.
- Perform security access again as indicated on the WDS or equivalent screen. (See NO.6 SECURITY ACCESS PROCEDURE
.)
- Select the replaced part as indicated on the WDS or equivalent screen.
- When replacing only the PCM: Select "PCM".
- When replacing only the instrument cluster: Select "HEC".
NOTE:
- At this time, do not select any other parts from the WDS or equivalent screen menu.
- Perform the tasks according to the WDS or equivalent screen.