Possible Causes
- A short to voltage in circuit (Y/V) or (L/GY)
- A short to ground in circuit (BR/L) or (L/GY)
- Smart junction box (SJB)
DTC B1405, DTC B1408 OR DTC B1410 - DRIVER POWER WINDOW SWITCH CIRCUIT SHORT TO BATTERY OR DRIVER POWER WINDOW MOTOR CIRCUIT FAILURE - PINPOINT TEST REFERENCE
| PINPOINT TEST 7 | DTC B1405, DTC B1408 OR DTC B1410 - DRIVER POWER WINDOW SWITCH CIRCUIT SHORT TO BATTERY OR DRIVER POWER WINDOW MOTOR CIRCUIT FAILURE | ||
|---|---|---|---|
| STEP | INSPECTION | ACTION | |
| 1 | CHECK SMART JUNCTION BOX (SJB) DTCs
|
Yes | Go to next step. |
| No | Go to step 4. | ||
| 2 | CHECK CIRCUIT (BR/L) AND (L/GY) FOR A SHORT TO GROUND
|
Yes | Go to next step. |
| No | Repair circuit (BR/L) or (L/GY) for a short to ground. Test the system for normal operation. | ||
| 3 | CHECK CIRCUIT (BR/L) AND (L/GY) FOR AN OPEN
|
Yes | Install a new SJB. See SMART JUNCTION BOX (SJB) , . Test the system for normal operation. |
| No | Repair circuit (BR/L) or (L/GY) for an open. Test the system for normal operation. | ||
| 4 | CHECK CIRCUIT (Y/V) AND (L/GY) FOR A SHORT TO VOLTAGE
|
Yes | Install a new SJB. See SMART JUNCTION BOX (SJB) , . Test the system for normal operation. |
| No | Repair circuit (Y/V) or (L/GY) for a short to voltage. Test the system for normal operation. | ||