Possible Causes
- Fuse(s)
- Smart junction box (SJB)
- Accessory relay
DELAYED ACCESSORY RELAY IS INOPERATIVE/DOES NOT OPERATE CORRECTLY - PINPOINT TEST REFERENCE
| PINPOINT TEST 5 | THE DELAYED ACCESSORY IS INOPERATIVE/DOES NOT OPERATE CORRECTLY | ||
|---|---|---|---|
| STEP | INSPECTION | ACTION | |
| 1 | CHECK ACCESSORY RELAY SUPPLY VOLTAGE
|
Yes | Go to next step. |
| No | Verify smart junction box (SJB) fuses 6 (10A) and 16 (30A) are OK. If the fuses are OK, install a new SJB. See SMART JUNCTION BOX (SJB) , . Test the system for normal operation. | ||
| 2 | CHECK ACCESSORY RELAY COIL VOLTAGE
|
Yes | Go to next step. |
| No | Install a new SJB. See SMART JUNCTION BOX (SJB) , . Test the system for normal operation. | ||
| 3 | CHECK ACCESSORY RELAY COIL GROUND CIRCUIT FOR AN OPEN
|
Yes | Install a new accessory relay. Test the system for normal operation. |
| No | Install a new SJB. See SMART JUNCTION BOX (SJB) , . Test the system for normal operation. | ||