Open circuit
- If there is no continuity, the circuit is open. Repair or replace the wiring harness.
- MAF/IAT sensor terminal A and main relay No.1 terminal D
- MAF/IAT sensor terminal C and PCM terminal 1AJ
- MAF/IAT sensor terminal D and PCM terminal 1 AN
- MAF/IAT sensor terminal E and PCM terminal 1AL