Intake Air Temperature (IAT) Sensor Inspection
- Remove the battery cover. (See BATTERY REMOVAL/INSTALLATION [LF, L5] .)
- Disconnect the negative battery cable.
- Disconnect the MAF/IAT sensor connector.
- Measure the resistance between the MAF/IAT sensor terminals D and E using an ohmmeter.
- If not as specified, replace the MAF/IAT sensor.
IAT sensor Specification
RESISTANCE CHART
| Ambient temperature (°C {°F}) | Resistance (kilohm) |
|---|---|
| 20 {68} | 2.21-2.69 |
| 60 {140} | 0.493-0.667 |