Continuity Inspection
- Remove the neutral switch. (See NEUTRAL SWITCH REMOVAL/INSTALLATION [M15M-D] ) (See NEUTRAL SWITCH REMOVAL/INSTALLATION [P66M-D] )
- Verify that the continuity between neutral switch terminals 1A and 2A is as indicated in the chart.
- If not as indicated in the chart, replace the neutral switch. (See NEUTRAL SWITCH REMOVAL/INSTALLATION [M15M-D] ) (See NEUTRAL SWITCH REMOVAL/INSTALLATION [P66M-D] )
- If the monitor item condition/specification (reference) is not within the specification, even though there is no malfunction, perform the "Circuit Open/Short Inspection".