Diagnostic Procedure
| Step | Inspection | Action | |
|---|---|---|---|
| 1 | PERFORM PCM DTC INSPECTION
|
Yes | Go to the applicable DTC inspection. (See DTC TABLE [MZR 2.5] .) (See DTC TABLE [MZI 3.7 V6] .) |
| No | Go to the next step. | ||
| 2 | INSPECT FUSE
|
Yes | Replace the MAIN 125 A, BTN 30 A and ROOM 15 A fuses, then go to Step 11. |
| No | Go to the next step. | ||
| 3 | INSPECT BATTERY
|
Yes | Recharge or replace the battery, then go to Step 11. (See BATTERY RECHARGING [MZR 2.5] .) (See BATTERY RECHARGING [MZI 3.7 V6] .) (See BATTERY REMOVAL/INSTALLATION [MZR 2.5] .) (See BATTERY REMOVAL/INSTALLATION [MZI 3.7 V6] .) |
| No | Go to the next step. | ||
| 4 | INSPECT GENERATOR
|
Yes | Replace the generator, then go to Step 11. (See GENERATOR REMOVAL/INSTALLATION [MZR 2.5] .) (See GENERATOR REMOVAL/INSTALLATION [MZI 3.7 V6] .) |
| No | Go to the next step. | ||
| 5 | INSPECT BCM CONNECTOR CONDITION
|
Yes | Repair or replace the connector or terminals, then go to Step 11. |
| No | Go to the next step. | ||
| 6 | INSPECT BATTERY POWER SUPPLY CIRCUIT (+B1) FOR SHORT TO GROUND OR OPEN CIRCUIT
|
Yes | Go to the next step. |
| No | Repair or replace the wiring harness for a possible short to ground or open circuit, then go to Step 11. | ||
| 7 | INSPECT KEYLESS CONTROL MODULE CONNECTOR CONDITION
|
Yes | Repair or replace the connector or terminals, then go to Step 11. |
| No | Go to the next step. | ||
| 8 | INSPECT BATTERY POWER SUPPLY CIRCUIT (+B1) FOR SHORT TO GROUND
|
Yes | Repair or replace the wiring harness for a possible short to ground, then go to Step 11. |
| No | Go to the next step. | ||
| 9 | INSPECT BATTERY POWER SUPPLY CIRCUIT (+B1) FOR OPEN CIRCUIT
|
Yes | Go to the next step. |
| No | Repair or replace the wiring harness for a possible open circuit, then go to Step 11. | ||
| 10 | INSPECT BCM
|
Yes | Go to the next step. |
| No | Replace the BCM, then go to the next step. (See BODY CONTROL MODULE (BCM) REMOVAL/INSTALLATION .) |
||
| 11 | VERIFY TROUBLESHOOTING COMPLETED
|
Yes | Repeat the inspection from Step 1. If the malfunction recurs, replace the keyless control module, then go to the next step. (See KEYLESS CONTROL MODULE REMOVAL/INSTALLATION [ADVANCED KEYLESS ENTRY AND PUSH BUTTON START SYSTEM] .) |
| No | Go to the next step. | ||
| 12 | VERIFY THAT NO OTHER DTCs ARE PRESENT
|
Yes | Go to the applicable DTC inspection. (See DTC TABLE [ADVANCED KEYLESS ENTRY AND PUSH BUTTON START SYSTEM] .) |
| No | DTC troubleshooting completed. | ||