Diagnostic Procedure
| Step | Inspection | Action | |
|---|---|---|---|
| 1 | INSPECT FUSE
|
Yes | Replace the ST SIG 5 A fuse, then go to Step 6. |
| No | Go to the next step. | ||
| 2 | INSPECT RELAY
|
Yes | Replace the starter relay, then go to Step 6. |
| No | Go to the next step. | ||
| 3 | INSPECT KEYLESS CONTROL MODULE CONNECTOR CONDITION
|
Yes | Repair or replace the connector or terminals, then go to Step 6. |
| No | Go to the next step. | ||
| 4 | INSPECT STARTER RELAY CIRCUIT FOR OPEN CIRCUIT
|
Yes | Go to the next step. |
| No | Repair or replace the wiring harness for a possible open circuit, then go to Step 6. | ||
| 5 | INSPECT KEYLESS CONTROL MODULE
|
Yes | Go to the next step. |
| No | Replace the keyless control module, then go to the next step. (See KEYLESS CONTROL MODULE REMOVAL/INSTALLATION [ADVANCED KEYLESS ENTRY AND PUSH BUTTON START SYSTEM] .) |
||
| 6 | VERIFY TROUBLESHOOTING COMPLETED
|
Yes | Repeat the inspection from Step 1. If the malfunction recurs, replace the keyless control module, then go to the next step. (See KEYLESS CONTROL MODULE REMOVAL/INSTALLATION [ADVANCED KEYLESS ENTRY AND PUSH BUTTON START SYSTEM] .) |
| No | Go to the next step. | ||
| 7 | VERIFY THAT NO OTHER DTCs ARE PRESENT
|
Yes | Go to the applicable DTC inspection. (See DTC TABLE [ADVANCED KEYLESS ENTRY AND PUSH BUTTON START SYSTEM] .) |
| No | DTC troubleshooting completed. | ||
| Step | Inspection | Action | |
|---|---|---|---|
| 1 | INSPECT KEYLESS CONTROL MODULE CONNECTOR CONDITION
|
Yes | Repair or replace the connector or terminals, then go to Step 4. |
| No | Go to the next step. | ||
| 2 | INSPECT STARTER RELAY CIRCUIT FOR OPEN CIRCUIT
|
Yes | Go to the next step. |
| No | Repair or replace the wiring harness for a possible open circuit, then go to Step 4. | ||
| 3 | INSPECT KEYLESS CONTROL MODULE
|
Yes | Go to the next step. |
| No | Replace the keyless control module, then go to the next step. (See KEYLESS CONTROL MODULE REMOVAL/INSTALLATION [ADVANCED KEYLESS ENTRY AND PUSH BUTTON START SYSTEM] .) |
||
| 4 | VERIFY TROUBLESHOOTING COMPLETED
|
Yes | Repeat the inspection from Step 1. If the malfunction recurs, replace the keyless control module, then go to the next step. (See KEYLESS CONTROL MODULE REMOVAL/INSTALLATION [ADVANCED KEYLESS ENTRY AND PUSH BUTTON START SYSTEM] .) |
| No | Go to the next step. | ||
| 5 | VERIFY THAT NO OTHER DTCs ARE PRESENT
|
Yes | Go to the applicable DTC inspection. (See DTC TABLE [ADVANCED KEYLESS ENTRY AND PUSH BUTTON START SYSTEM] .) |
| No | DTC troubleshooting completed. | ||
| Step | Inspection | Action | |
|---|---|---|---|
| 1 | INSPECT FUSE
|
Yes | Replace the ST SIG 5 A fuse, then go to Step 5. |
| No | Go to the next step. | ||
| 2 | INSPECT RELAY
|
Yes | Replace the starter relay, then go to Step 5. |
| No | Go to the next step. | ||
| 3 | INSPECT KEYLESS CONTROL MODULE CONNECTOR CONDITION
|
Yes | Repair or replace the connector or terminals, then go to Step 5. |
| No | Go to the next step. | ||
| 4 | INSPECT KEYLESS CONTROL MODULE
|
Yes | Go to the next step. |
| No | Replace the keyless control module, then go to the next step. (See KEYLESS CONTROL MODULE REMOVAL/INSTALLATION [ADVANCED KEYLESS ENTRY AND PUSH BUTTON START SYSTEM] .) |
||
| 5 | VERIFY TROUBLESHOOTING COMPLETED
|
Yes | Repeat the inspection from Step 1. If the malfunction recurs, replace the keyless control module, then go to the next step. (See KEYLESS CONTROL MODULE REMOVAL/INSTALLATION [ADVANCED KEYLESS ENTRY AND PUSH BUTTON START SYSTEM] .) |
| No | Go to the next step. | ||
| 6 | VERIFY THAT NO OTHER DTCs ARE PRESENT
|
Yes | Go to the applicable DTC inspection. (See DTC TABLE [ADVANCED KEYLESS ENTRY AND PUSH BUTTON START SYSTEM] .) |
| No | DTC troubleshooting completed. | ||