DTC U0233: 00 Communication Error With BSM Control Module (RH): Notes
DTC U0233:00 DETECTION CONDITIONS AND POSSIBLE CAUSE
| Description |
Communication error with BSM control module (RH) |
| Detection condition |
- No communication between BSM control module (LH) and (RH) for 1 s or more
.
|
| Fail-safe function |
- Blind spot monitoring (BSM) system is stopped.
|
| Possible cause |
- BSM control module (RH) connector or terminal malfunction
- BSM control module (LH) connector or terminal malfunction
- Short to ground in wiring harness between the following terminals:
- BSM control module (LH) terminal A-BSM control module (RH) terminal A
- BSM control module (LH) terminal B-BSM control module (RH) terminal B
- Short to power supply in wiring harness between the following terminals:
- BSM control module (LH) terminal A-BSM control module (RH) terminal A
- BSM control module (LH) terminal B-BSM control module (RH) terminal B
- Open circuit in wiring harness between the following terminals:
- BSM control module (LH) terminal A-BSM control module (RH) terminal A
- BSM control module (LH) terminal B-BSM control module (RH) terminal B
- BSM control module (RH) malfunction
- BSM control module (LH) malfunction
|
|
|