Diagnostic Procedure
DOOR GLASS DIAGNOSTIC PROCEDURE
| Step | Inspection | Action | |
|---|---|---|---|
| 1 | VERIFY IF MALFUNCTION CAUSE IS OPERATION UNDER OPERATION PERMISSION CONDITION
|
Yes | System is normal. (Tell the customer about the power-cut switch.) |
| No | Go to the next step. | ||
| 2 | POWER WINDOW SUBSWITCH CONNECTOR INSPECTION
|
Yes | Go to the next step. |
| No | Repair or replace the connector, then go to Step 4. | ||
| 3 | VERIFY IF MALFUNCTION CAUSE IS POWER WINDOW SUBSWITCH POWER SUPPLY CIRCUIT
|
Yes | Replace the power window subswitch, then go to the next step. (See POWER WINDOW SUBSWITCH REMOVAL/INSTALLATION .) |
| No | Inspect the P.WINDOW1 30A fuse.
Go to the next step. |
||
| 4 | VERIFY IF MALFUNCTION CAUSE IS CORRECTED
|
Yes | Troubleshooting completed. (Explain the problem to the customer.) |
| No | Verify the malfunction symptom in the symptom troubleshooting chart and perform the other applicable malfunction diagnosis. | ||