ECT Sensor No 2
- Disconnect the negative battery cable. (See NEGATIVE BATTERY CABLE DISCONNECTION/CONNECTION [SKYACTIV-G 2.0, SKYACTIV-G 2.5] .)
- Drain the engine coolant. (See ENGINE COOLANT REPLACEMENT .)
- Remove the plug hole plate. (See PLUG HOLE PLATE REMOVAL/INSTALLATION .)
- Disconnect the ECT sensor No. 2 connector. (See ENGINE COOLANT TEMPERATURE (ECT) SENSOR REMOVAL/INSTALLATION .)
- Remove the ECT sensor No. 2. (See ENGINE COOLANT TEMPERATURE (ECT) SENSOR REMOVAL/INSTALLATION .)
- Place the ECT sensor No. 2 in water with a thermometer, and heat the water gradually.
- Measure the resistance between ECT sensor No. 2 terminals A and B.
- If not as specified, replace the ECT sensor No. 2. (See ENGINE COOLANT TEMPERATURE (ECT) SENSOR REMOVAL/INSTALLATION .)
CONTINUITY SPECIFICATION
| ECT (°C {°F}) | Resistance (Kilohms) |
|---|---|
| 20 {68} | Approx. 2.45 |
| 80 {176} | Approx. 0.318 |