DTC B1455-23: Power Liftgate (PLG) Touch Sensor (RH) Circuit Malfunction: Notes

Description  Power liftgate (PLG) touch sensor (RH) circuit malfunction
Detection condition 
  • Power liftgate (PLG) control module detected a short circuit to ground in the power liftgate (PLG) touch sensor (RH) circuit for 5 min or more.
Fail-safe 
  • Stops the power liftgate (PLG) system operation.
Possible cause 
  • Power liftgate (PLG) touch sensor (RH) connector or terminal malfunction
  • Power liftgate (PLG) control module connector or terminal malfunction
  • Short to ground in wiring harness between power liftgate (PLG) touch sensor (RH) terminal B and power liftgate (PLG) control module terminal 1P
  • Power liftgate (PLG) touch sensor (RH) malfunction
  • Power liftgate (PLG) control module malfunction
G10949029