| B11CB:11 |
Blind spot monitoring (BSM) warning light (RH) circuit malfunction |
(See DTC B11CB:11 [BLIND SPOT MONITORING (BSM) CONTROL MODULE]
.) |
| B11CB:15 |
Blind spot monitoring (BSM) warning light (RH) circuit malfunction |
(See DTC B11CB:15 [BLIND SPOT MONITORING (BSM) CONTROL MODULE]
.) |
| B11D3:11 |
Blind spot monitoring (BSM) warning light (LH) circuit malfunction |
(See DTC B11D3:11 [BLIND SPOT MONITORING (BSM) CONTROL MODULE]
.) |
| B11D3:15 |
Blind spot monitoring (BSM) warning light (LH) circuit malfunction |
(See DTC B11D3:15 [BLIND SPOT MONITORING (BSM) CONTROL MODULE]
.) |
| B11F2:23 |
Blind spot monitoring (BSM) switch circuit malfunction |
(See DTC B11F2:23 [BLIND SPOT MONITORING (BSM) CONTROL MODULE]
.) |
| U0001:88 |
Unit communication error (MS-CAN) |
(See DTC U0001:88/U0100:00/U0121:00/U0155:00/U0214:00 [BLIND SPOT MONITORING (BSM) CONTROL MODULE]
.) |
| U0028:87 |
Blind spot monitoring (BSM) control module (LH) and (RH) communication error |
(See DTC U0028:87 [BLIND SPOT MONITORING (BSM) CONTROL MODULE]
.) |
| U0100:00 |
Communication error with PCM |
(See DTC U0001:88/U0100:00/U0121:00/U0155:00/U0214:00 [BLIND SPOT MONITORING (BSM) CONTROL MODULE]
.) |
| U0121:00 |
Communication error with DSC HU/CM |
| U0155:00 |
Communication error with instrument cluster |
| U0214:00 |
Communication error with start stop unit |
| U0401:68 |
Error signal received from PCM |
(See DTC U0401:68 [BLIND SPOT MONITORING (BSM) CONTROL MODULE]
.) |
| U0415:68 |
Error signal received from DSC HU/CM |
(See DTC U0415:68 [BLIND SPOT MONITORING (BSM) CONTROL MODULE]
.) |
| U0423:68 |
Error signal received from instrument cluster |
(See DTC U0423:68 [BLIND SPOT MONITORING (BSM) CONTROL MODULE]
.) |
| U0515:68 |
Error signal received from start stop unit |
(See DTC U0515:68 [BLIND SPOT MONITORING (BSM) CONTROL MODULE]
.) |
| U1A4B:16 |
Blind spot monitoring (BSM) control module (RH) low power supply voltage input |
(See DTC U1A4B:16 [BLIND SPOT MONITORING (BSM) CONTROL MODULE]
.) |
| U1A4B:17 |
Blind spot monitoring (BSM) control module (RH) high power supply voltage input |
(See DTC U1A4B:17 [BLIND SPOT MONITORING (BSM) CONTROL MODULE]
.) |
| U1A4B:43 |
Blind spot monitoring (BSM) control module (RH) malfunction |
(See DTC U1A4B:43/U1A4B:44/U1A4B:45/U1A4B:46/U1A4B:47/U1A4B:48/U1A4B:49/U1A4B:96 [BLIND SPOT MONITORING (BSM) CONTROL MODULE]
.) |
| U1A4B:44 |
Blind spot monitoring (BSM) control module (RH) malfunction |
| U1A4B:45 |
Blind spot monitoring (BSM) control module (RH) malfunction |
| U1A4B:46 |
Blind spot monitoring (BSM) control module (RH) malfunction |
| U1A4B:47 |
Blind spot monitoring (BSM) control module (RH) malfunction |
| U1A4B:48 |
Blind spot monitoring (BSM) control module (RH) malfunction |
| U1A4B:49 |
Blind spot monitoring (BSM) control module (RH) malfunction |
| U1A4B:54 |
Radar aiming is not performed or radar sensor axis is deviated (blind spot monitoring (BSM) control module (RH)) |
(See DTC U1A4B:54 [BLIND SPOT MONITORING (BSM) CONTROL MODULE]
.) |
| U1A4B:96 |
Blind spot monitoring (BSM) control module (RH) malfunction |
(See DTC U1A4B:43/U1A4B:44/U1A4B:45/U1A4B:46/U1A4B:47/U1A4B:48/U1A4B:49/U1A4B:96 [BLIND SPOT MONITORING (BSM) CONTROL MODULE]
.) |
| U1A4B:97 |
Radar sensor sensitivity temporarily decreases depending on various external and environmental factors (blind spot monitoring (BSM) control module (RH)) |
(See DTC U1A4B:97 [BLIND SPOT MONITORING (BSM) CONTROL MODULE]
.) |
| U2300:54 |
Configuration data not received from instrument cluster |
(See DTC U2300:54 [BLIND SPOT MONITORING (BSM) CONTROL MODULE]
.) |
| U2300:55 |
Instrument cluster configuration not implemented |
(See DTC U2300:55 [BLIND SPOT MONITORING (BSM) CONTROL MODULE]
.) |
| U2300:56 |
Configuration data unmatched with instrument cluster |
(See DTC U2300:56 [BLIND SPOT MONITORING (BSM) CONTROL MODULE]
.) |
| U2300:64 |
Instrument cluster configuration error |
(See DTC U2300:64 [BLIND SPOT MONITORING (BSM) CONTROL MODULE]
.) |
| U3000:42 |
Blind spot monitoring (BSM) control module (LH) malfunction |
(See DTC U3000:42/U3000:43/U3000:44/U3000:45/U3000:46/U3000:47/U3000:48/U3000:49/U3000:96 [BLIND SPOT MONITORING (BSM) CONTROL MODULE]
.) |
| U3000:43 |
Blind spot monitoring (BSM) control module (LH) malfunction |
| U3000:44 |
Blind spot monitoring (BSM) control module (LH) malfunction |
| U3000:45 |
Blind spot monitoring (BSM) control module (LH) malfunction |
| U3000:46 |
Blind spot monitoring (BSM) control module (LH) malfunction |
| U3000:47 |
Blind spot monitoring (BSM) control module (LH) malfunction |
| U3000:48 |
Blind spot monitoring (BSM) control module (LH) malfunction |
| U3000:49 |
Blind spot monitoring (BSM) control module (LH) malfunction |
| U3000:4B |
Temperature temporarily increases depending on various external and environmental factors (blind spot monitoring (BSM) control module (LH) or (RH)) |
(See DTC U3000:4B [BLIND SPOT MONITORING (BSM) CONTROL MODULE]
.) |
| U3000:54 |
Radar aiming is not performed or radar sensor axis is deviated (blind spot monitoring (BSM) control module (LH)) |
(See DTC U3000:54 [BLIND SPOT MONITORING (BSM) CONTROL MODULE]
.) |
| U3000:96 |
Blind spot monitoring (BSM) control module (LH) malfunction |
(See DTC U3000:42/U3000:43/U3000:44/U3000:45/U3000:46/U3000:47/U3000:48/U3000:49/U3000:96 [BLIND SPOT MONITORING (BSM) CONTROL MODULE]
.) |
| U3000:97 |
Radar sensor sensitivity temporarily decreases depending on various external and environmental factors (blind spot monitoring (BSM) control module (LH)) |
(See DTC U3000:97 [BLIND SPOT MONITORING (BSM) CONTROL MODULE]
.) |
| U3003:16 |
Blind spot monitoring (BSM) control module (LH) low power supply voltage input |
(See DTC U3003:16 [BLIND SPOT MONITORING (BSM) CONTROL MODULE]
.) |
| U3003:17 |
Blind spot monitoring (BSM) control module (LH) high power supply voltage input |
(See DTC U3003:17 [BLIND SPOT MONITORING (BSM) CONTROL MODULE]
.) |