Refrigerant Pressure Sensor Removal/Installation (Auto A/C): Notes
- Disconnect the negative battery cable.
- Discharge the refrigerant. (See REFRIGERANT CHARGING .)
- Disconnect the refrigerant pressure sensor connector.CAUTION:
- If moisture or foreign material enters the refrigeration cycle, cooling ability will be lowered and abnormal noise will occur. Always immediately plug all open fittings after removing any refrigeration cycle parts to keep moisture or foreign material out of the cycle.
- Loosen the refrigerant pressure sensor using two spanners.
- Remove the refrigerant pressure sensor. (See REFRIGERANT PRESSURE SENSOR INSTALLATION NOTE .)
Tightening torque
9.5-11.5 N.m {102-112 kgf.cm, 89-97 in.lbf}
- Install in the reverse order of removal.
- Perform the refrigerant system performance test. (See REFRIGERANT SYSTEM PERFORMANCE TEST .)