Determining Open Circuit Location (HS-Can) [With Occupant Classification Sensor]: W: Notes
Possible cause
- Connector terminal disconnection, poor contact, damage, deformation, corrosion
- Connectivity master unit (CMU) power supply voltage or body ground malfunction
- Open circuit in wiring harness between connectivity master unit (CMU) and connector C-35
- Connector C-35 malfunction
- Connectivity master unit (CMU) malfunction