DTC B00A0-54: Occupant Classification Sensor Calibration Setting Not Set: Notes
DTC B00A0:54 SAS CONTROL MODULE (TWO-STEP DEPLOYMENT CONTROL SYSTEM - US/CANADA SPEC.) DETECTION CONDITION AND POSSIBLE CAUSE
| System malfunction location |
- Occupant classification sensor calibration setting not set
|
| Detection condition |
WARNING:
- Detection conditions are for understanding the DTC outline before performing an inspection. Performing an inspection according to only the detection conditions may cause injury due to an operating error, or damage the system. When performing an inspection, always follow the inspection procedure.
- Occupant classification sensor calibration setting has not been done correctly
|
| Fail-safe |
Not applicable |
| Possible cause |
- Occupant classification sensor calibration setting not implemented
- Occupant classification sensor calibration setting invalid
- Occupant classification sensor malfunction
|
| System wiring diagram |
Not applicable |