Diagnostic Procedure
| Step | Inspection | Action | |
|---|---|---|---|
| 1 | INSPECT OCCUPANT CLASSIFICATION SENSOR CONNECTOR
WARNING:
|
Yes | Replace the malfunctioning part, then go to Step 5. |
| No | Go to the next step. | ||
| 2 | INSPECT OCCUPANT CLASSIFICATION SENSOR CIRCUIT FOR SHORT TO GROUND
|
Yes | Replace the wiring harness for a possible short to ground, then go to Step 5. |
| No | Go to the next step. | ||
| 3 | INSPECT OCCUPANT CLASSIFICATION SENSOR CIRCUIT FOR OPEN CIRCUIT
|
Yes | Go to the next step. |
| No | Replace the wiring harness for a possible open circuit, then go to Step 5. | ||
| 4 | INSPECT OCCUPANT CLASSIFICATION SENSOR CIRCUIT FOR SHORT TO POWER SUPPLY
|
Yes | Go to the next step. |
| No | Replace the wiring harness for a possible short to power supply, then go to the next step. | ||
| 5 | INSPECT OCCUPANT CLASSIFICATION SENSOR
|
Yes | Go to the next step. |
| No | Repair or replace the wiring harness or connector, then go to the next step. | ||
| 6 | PERFORM SAS CONTROL MODULE DTC INSPECTION
|
Yes | Replace the occupant classification sensor. (See OCCUPANT CLASSIFICATION SENSOR REMOVAL/INSTALLATION [TWO-STEP DEPLOYMENT SYSTEM] ). Then go to the next step. |
| No | DTC troubleshooting completed. | ||
| 7 | VERIFY TROUBLESHOOTING COMPLETED
|
Yes | Replace the SAS control module. (See SAS CONTROL MODULE REMOVAL/INSTALLATION [TWO-STEP DEPLOYMENT CONTROL SYSTEM] ). |
| No | DTC troubleshooting completed. | ||