DTC B00D5:01/B00D5:29 - SAS CONTROL MODULE (TWO-STEP DEPLOYMENT CONTROL SYSTEM) DIAGNOSTIC PROCEDURE
| Step | Inspection | Action | |
|---|---|---|---|
| 1 | INSPECT DTCs IN SAS CONTROL MODULE
|
Yes | Perform the applicable DTC inspection. |
| No | Go to the next step. | ||
| 2 | PERFORM INSTRUMENT CLUSTER DTC INSPECTION
|
Yes | Perform the applicable DTC inspection. (See DTC TABLE [INSTRUMENT CLUSTER] .) |
| No | Go to the next step. | ||
| 3 | INSPECT INDICATOR UNIT
|
Yes | Go to the next step. |
| No | Replace the indicator unit. (See INDICATOR UNIT REMOVAL/INSTALLATION
.) Then go to Step 9. |
||
| 4 | INSPECT SAS CONTROL MODULE CONNECTOR
WARNING:
|
Yes | Replace the malfunctioning part, then go to the next step. |
| No | Go to the next step. | ||
| 5 | INSPECT INSTRUMENT CLUSTER CONNECTOR
|
Yes | Replace the malfunctioning part, then go to the next step. |
| No | Go to the next step. | ||
| 6 | INSPECT INDICATOR UNIT CONNECTOR
|
Yes | Replace the malfunctioning part, then go to the next step. |
| No | Go to the next step. | ||
| 7 | INSPECT INDICATOR UNIT CIRCUIT FOR OPEN CIRCUIT
NOTE:
|
Yes | Go to the next step. |
| No | Refer to the wiring diagram and verify whether or not there is a common connector between indicator unit terminal and instrument cluster terminal. If there is a common connector:
|
||
| 8 | INSPECT INDICATOR UNIT CIRCUIT FOR SHORT TO POWER SUPPLY
NOTE:
|
Yes | Replace the instrument cluster. (See INSTRUMENT CLUSTER REMOVAL/INSTALLATION
.) Then go to the next step. |
| No | Refer to the wiring diagram and verify whether or not there is a common connector between indicator unit terminal and instrument cluster terminal. If there is a common connector:
|
||
| 9 | PERFORM SAS CONTROL MODULE DTC INSPECTION
|
Yes | Replace the SAS control module. (See SAS CONTROL MODULE REMOVAL/INSTALLATION [TWO-STEP DEPLOYMENT CONTROL SYSTEM] .) |
| No | DTC troubleshooting completed. | ||