DTC C0061-29/C0062-29/C0063-29/P0666-29: Sensor In SAS Control Module (Internal Circuit Disabled) [SAS Control Module (Two-Step Deployment Control System)]: Notes
DTC C0061:29/C0062:29/C0063:29/P0666:29 - SAS CONTROL MODULE (TWO-STEP DEPLOYMENT CONTROL SYSTEM) DETECTION CONDITION AND POSSIBLE CAUSE
| System malfunction location |
- C0061:29: Low-G sensor (lateral-G) in SAS control module (internal circuit disabled)
- C0062:29: Low-G sensor (forward-G) in SAS control module (internal circuit disabled)
- C0063:29: Yaw rate sensor in SAS control module (internal circuit disabled)
- P0666:29: Temperature sensor in SAS control module (internal circuit disabled)
|
| Detection condition |
WARNING:
- Detection conditions are for understanding the DTC outline before performing an inspection. Performing an inspection according to only the detection conditions may cause injury due to an operating error, or damage the system. When performing an inspection, always follow the inspection procedure.
- SAS control module internal sensor has a malfunction
|
| Fail-safe |
Not applicable |
| Possible cause |
- SAS control module malfunction
|
| System wiring diagram |
Not applicable |