PID/DATA MONITOR DESCRIPTION

PID Unit/Operation Data Module control terminal
BCM_ID_RGTR NotComplete/Complete
  • NotComplete: Programming of remote transmitter ID data between body control module (BCM) and liftgate control module is not completed.
  • Complete: Programming of remote transmitter ID data between body control module (BCM) and liftgate control module is completed.
-
CARGO_LAMP_SW Off/On
  • Off: Room light switch is off.
  • On: Room light switch is on.
2AC
CLAW_SW Off/On
  • Off: Claw switch is off.
  • On: Claw switch is on.
2AA
CLOSURE_MOTOR_CLOSE_STAT Off/On
  • Off: Closure motor close is not operating.
  • On: Closure motor close is operating.
-
CLOSURE_MOTOR_CLOSE_VOLT V Displays the voltage during a close operation of the closure motor. 1F
CLOSURE_MOTOR_CUR A Displays the current during closure motor operation. -
CLOSURE_MOTOR_OPEN_STAT Off/On
  • Off: Closure motor open is not operating.
  • On: Closure motor open is operating.
-
CLOSURE_MOTOR_OPEN_VOLT V Displays the voltage during a open operation of the closure motor. 1H
HALF_LATCH_SW Off/On
  • Off: Half latch switch is off.
  • On: Half latch switch is on.
2Y
PLG_MOTOR_CLOSE_STAT_L Off/On
  • Off: Power liftgate drive unit motor (LH) close is not operating.
  • On: Power liftgate drive unit motor (LH) close is operating.
-
PLG_MOTOR_CLOSE_STAT_R Off/On
  • Off: Power liftgate drive unit motor (RH) close is not operating.
  • On: Power liftgate drive unit motor (RH) close is operating.
-
PLG_MOTOR_CLOSE_VOLT_L V Displays the voltage during a close operation of the power liftgate drive unit motor (LH). 1G
PLG_MOTOR_CLOSE_VOLT_R V Displays the voltage during a close operation of the power liftgate drive unit motor (RH). 1C
PLG_MOTOR_CUR_L A Displays the current during power liftgate drive unit motor (LH) operation. -
PLG_MOTOR_CUR_R A Displays the current during power liftgate drive unit motor (RH) operation. -
PLG_MOTOR_OPEN_STAT_L Off/On
  • Off: Power liftgate drive unit motor (LH) open is not operating.
  • On: Power liftgate drive unit motor (LH) open is operating.
-
PLG_MOTOR_OPEN_STAT_R Off/On
  • Off: Power liftgate drive unit motor (RH) open is not operating.
  • On: Power liftgate drive unit motor (RH) open is operating.
-
PLG_MOTOR_OPEN_VOLT_L V Displays the voltage during a open operation of the power liftgate drive unit motor (LH). 1E
PLG_MOTOR_OPEN_VOLT_R V Displays the voltage during a open operation of the power liftgate drive unit motor (RH). 1A
PLG_PULSE_COUNT_L Count Displays pulse count from the power liftgate drive unit (LH) 2H, 2J
PLG_PULSE_COUNT_R Count Displays pulse count from the power liftgate drive unit (RH) 2K, 2M
PLG_SEN_A_L Lo/Hi
  • Low: Hall effect switch 1 (LH) in power liftgate (PLG) drive unit (LH) is on.
  • High: Hall effect switch 1 (LH) in power liftgate (PLG) drive unit (LH) is off.
2H
PLG_SEN_A_R Lo/Hi
  • Low: Hall effect switch 1 (RH) in power liftgate (PLG) drive unit (RH) is on.
  • High: Hall effect switch 1 (RH) in power liftgate (PLG) drive unit (RH) is off.
2K
PLG_SEN_B_L Lo/Hi
  • Low: Hall effect switch 2 (LH) in power liftgate (PLG) drive unit (LH) is on.
  • High: Hall effect switch 2 (LH) in power liftgate (PLG) drive unit (LH) is off.
2J
PLG_SEN_B_R Lo/Hi
  • Low: Hall effect switch 2 (RH) in power liftgate (PLG) drive unit (RH) is on.
  • High: Hall effect switch 2 (RH) in power liftgate (PLG) drive unit (RH) is off.
2M
PLG_STAT Unknown/PLG FullClose/PLG
HalfOpen/PLG FullOpen/PLG
AutoOpen/PLG AutoClose
  • Unknown: Liftgate operation condition is not determined.
  • PLG FullClose: Liftgate is fully closed.
  • PLG HalfOpen: Liftgate is partly open.
  • PLG FullOpen: Liftgate is fully open.
  • PLG AutoOpen: Liftgate is during auto open operation.
  • PLG AutoClose: Liftgate is during auto close operation.
2A, 2B
RETURN_SW Off/On
  • Off: Motor return switch is off.
  • On: Motor return switch is on.
2AB
TOUCH_SEN_L V Displays voltage at the power liftgate touch sensor (LH) 2N
TOUCH_SEN_R V Displays voltage at the power liftgate touch sensor (RH) 2L
VPWR V Displays voltage at the power supply -
VPWR_IG V Displays power supply voltage of power liftgate control module 2W
VPWR_POWER V Displays power supply voltage of power liftgate control module 1B
VPWR_SEN_SW V Displays power supply voltage of power liftgate control module 2X