Diagnostic Procedure
DTC U0031:86 (RETRACTABLE HARDTOP CONTROL MODULE) DIAGNOSTIC PROCEDURE
| Step | Inspection | Action | |
|---|---|---|---|
| 1 | VERIFY OTHER RETRACTABLE HARDTOP CONTROL MODULE DTCs
|
Yes | Replace the retractable hardtop control module, then go to Step 5. (See RETRACTABLE HARDTOP CONTROL MODULE REMOVAL/INSTALLATION .) |
| No | Go to the next step. | ||
| 2 | INSPECT POWER WINDOW MAIN SWITCH CIRCUIT FOR SHORT TO GROUND
|
Yes | Refer to the wiring diagram and verify whether or not there is a common connector between the following terminals:
If there is a common connector:
If there is no common connector:
|
| No | Go to the next step. | ||
| 3 | INSPECT POWER WINDOW MAIN SWITCH CIRCUIT FOR SHORT TO POWER SUPPLY
|
Yes | Go to the next step. |
| No | Refer to the wiring diagram and verify whether or not there is a common connector between the following terminals:
If there is a common connector:
If there is no common connector:
|
||
| 4 | INSPECT POWER WINDOW MAIN SWITCH
|
Yes | Go to the next step. |
| No | Replace the power window main switch, then go to the next step. (See POWER WINDOW MAIN SWITCH REMOVAL/INSTALLATION .) |
||
| 5 | VERIFY THAT REPAIRS HAVE BEEN COMPLETED
|
Yes | Repeat the inspection from Step 1.
|
| No | Go to the next step. | ||
| 6 | VERIFY IF OTHER DTCs DISPLAYED
|
Yes | Repair or replace the malfunctioning part according to the applicable DTC troubleshooting. (See DTC TABLE [RETRACTABLE HARDTOP CONTROL MODULE] .) |
| No | DTC troubleshooting completed. | ||