Diagnostic Procedure
DTC B1495:55 [POWER LIFTGATE (PLG) CONTROL MODULE] DIAGNOSTIC PROCEDURE
| Step | Inspection | Action | |
|---|---|---|---|
| 1 | VERIFY IF OTHER DTCs DISPLAYED FOR POWER LIFTGATE (PLG) CONTROL MODULE
|
Yes | Replace the power liftgate (PLG) control module, then go to step 7. (See POWER LIFTGATE (PLG) CONTROL MODULE REMOVAL/INSTALLATION .) |
| No | Go to the next step. | ||
| 2 | VERIFY INSTRUMENT CLUSTER DTCs
|
Yes | Repair the malfunctioning part according to the applicable DTC troubleshooting. (See DTC TABLE [INSTRUMENT CLUSTER] .) |
| No | Go to the next step. | ||
| 3 | INSPECT FOOT-MOTION DETECTION UNIT CIRCUIT FOR SHORT TO GROUND
|
Yes | Refer to appropriate wiring diagram and verify whether or not there is a common connector between foot-motion detection unit terminal 1C and power liftgate (PLG) control module terminal 1C. If there is a common connector:
If there is no common connector:
Go to Step 7. |
| No | Go to the next step. | ||
| 4 | INSPECT FOOT-MOTION DETECTION UNIT CIRCUIT FOR SHORT TO POWER SUPPLY
|
Yes | Go to next step. |
| No | Refer to appropriate wiring diagram and verify whether or not there is a common connector between foot-motion detection unit terminal 1C and power liftgate (PLG) control module terminal 1C. If there is a common connector:
If there is no common connector:
Go to Step 7. |
||
| 5 | INSPECT FOOT-MOTION DETECTION UNIT CIRCUIT FOR OPEN CIRCUIT
|
Yes | Go to the next step. |
| No | Refer to appropriate wiring diagram and verify whether or not there is a common connector between foot-motion detection unit terminal 1C and power liftgate (PLG) control module terminal 1C. If there is a common connector:
If there is no common connector:
Go to Step 7. |
||
| 6 | RESET INSTRUMENT CLUSTER CONFIGURATION DATA
|
Yes | Using the M-MDS, perform the instrument cluster configuration (using As-Built data) again, then go to the next step. (See INSTRUMENT CLUSTER CONFIGURATION (USING AS-BUILT DATA) .) |
| No | Go to Step 9. | ||
| 7 | VERIFY IF MALFUNCTIONING LOCATION IS FOOT-MOTION DETECTION UNIT DEPENDING ON REPEATABILITY
|
Yes | Replace the foot-motion detection unit, then go to the next step. (See FOOT-MOTION DETECTION UNIT REMOVAL/INSTALLATION .) |
| No | Go to Step 9. | ||
| 8 | VERIFY THAT REPAIRS HAVE BEEN COMPLETED
|
Yes | Replace the power liftgate (PLG) control module, then go to the next step. (See POWER LIFTGATE (PLG) CONTROL MODULE REMOVAL/INSTALLATION .) |
| No | Go to the next step. | ||
| 9 | VERIFY IF OTHER DTCs DISPLAYED
|
Yes | Repair or replace the malfunctioning part according to the applicable DTC troubleshooting. (See DTC TABLE [POWER LIFTGATE (PLG) CONTROL MODULE] .) |
| No | DTC troubleshooting completed. | ||