DTC U2300-56: Configuration Data Unmatched With Instrument Cluster [Power Liftgate (PLG) Control Module]: Notes
DTC U2300:56 [POWER LIFTGATE (PLG) CONTROL MODULE] DETECTION CONDITION AND POSSIBLE CAUSE
| Description |
Configuration data unmatched with instrument cluster |
| Detection condition |
- Configuration data of the power liftgate (PLG) control module and instrument cluster are not matched.
|
| Fail-safe |
- Stops the power liftgate (PLG) system operation.
|
| Possible cause |
NOTE:
- To correctly write the configuration data sent from the instrument cluster to the power liftgate (PLG) control module to the power liftgate (PLG) control module, 30 s or more need to have elapsed since the ignition was switched ON (engine off or on).
- DTCs are stored in the instrument cluster.
- Instrument cluster configuration not implemented
- Instrument cluster internal memory malfunction
- Instrument cluster configuration data error
- Power liftgate (PLG) control module malfunction
|
| System wiring diagram |
Not applicable |