Diagnostic Procedure
DTC B10D3:23 (START STOP UNIT) DIAGNOSTIC PROCEDURE
| Step | Inspection | Action | |
|---|---|---|---|
| 1 | INSPECT OUTER HANDLE (RH) CONNECTOR CONDITION
|
Yes | Go to the next step. |
| No | Repair or replace the connector, then go to Step 6. | ||
| 2 | INSPECT LF CONTROL UNIT CONNECTOR CONDITION
|
Yes | Go to the next step. |
| No | Repair or replace the connector, then go to Step 6. | ||
| 3 | INSPECT REQUEST SWITCH (RF) CIRCUIT FOR SHORT TO GROUND
|
Yes | Refer to the wiring diagram and verify whether or not there is a common connector between LF control unit terminal A and outer handle (RH) terminal D. If there is a common connector:
If there is no common connector:
Go to Step 6. |
| No | Go to the next step. | ||
| 4 | INSPECT REQUEST SWITCH (RF)
|
Yes | Go to the next step. |
| No | Replace the outer handle (RH), then go to Step 6. (See OUTER HANDLE REMOVAL/INSTALLATION .) | ||
| 5 | INSPECT LF CONTROL UNIT
|
Yes | Go to the next step. |
| No | Replace the LF control unit, then go to the next step. (See LF CONTROL UNIT REMOVAL/INSTALLATION .) | ||
| 6 | VERIFY THAT REPAIRS HAVE BEEN COMPLETED
|
Yes | Repeat the inspection from Step 1.
|
| No | Go to the next step. | ||
| 7 | VERIFY IF OTHER DTCs DISPLAYED
|
Yes | Repair or replace the malfunctioning part according to the applicable DTC troubleshooting. (See DTC TABLE [START STOP UNIT] .) |
| No | DTC troubleshooting completed. | ||