Glass breakage sensor, function - GF80.50-P-4107-02A
Models 202.07/08/18, model 210.2
When a window is broken the conductor circuit is interrupted. This interruption in the circuit is registered by the left or right infrared transmitter and receiver (A26/4, A26/5) .
On the 210 T-model the rear window defroster element (R1) is used as the sensor for the rear window. An interruption in this circuit is registered by the PSE control module (combined) (A37).