Programming of control units with Flash Support File - AR54.21-P-0014Z: Notes
MODEL 129.058 /063 /067 /076, 163, 164, 168, 169, 170, 171.4, 199, 203, 204, 208, 209, 211, 215, 216, 219, 220, 221, 230, 240, 245, 251, 461.302 /331 /332 /342 /345, 463.206 /208 /209 /232 /233 /240 /241 /243 /244 /245 /246 /247 /248 /249 /250 /254 /270 /271 /303 /308 /309 /322 /323 /332 /333 /340 /341, 450, 451, 452, 454 Offline programming with SD flash Special Release CD
| Notes on programming control units | AH54.21-P-0001-03Z | |||
| Program with Flash Support File (support through User Help Desk) | ||||
| 1 | Connect diagnosis system, start "Xentry Diagnostics" (XD) and select vehicle model | AD00.00-P-2000-04A | ||
Otherwise, any undervoltage may damage the control units. |
||||
| 2 | Determine the part number of the control unit with the help of the current parts catalog | Only required if data cannot be read out of the control unit. | ||
| 3 | Select the "Adaptations" menu item in the control unit | |||
| 4 | Select Query control unit software | |||
| 5 | Save query data to "User Help Desk" | |||
| 6 | Send query data to "User Help Desk" | |||
| 7 | Determine control unit software | |||
| 8 | Load response data and program control unit | |||
| 9 | Contact "User Help Desk Star Diagnosis" | Only if the control unit does not communicate with the XD or the problem cannot be eliminated using the current XD-DVD. |
||
| 10 | Forward flash/code support package, control unit version and, where applicable, the repair job documentation to the "Star Diagnosis User Help Desk" | Star Diagnosis User Help Desk sends the Flash Support File electronically to the workshop. |
||
| 11 | Carry out re-documentation procedure in Vehicle Documentation (VeDoc) in VeDoc screen | Only after successful programming of the control unit. | ||
| 12 | Perform software calibration number (SCN) coding for control units | Only when required | AR54.21-P-0015X | |
| 13 | Run teach-in procedures | Only when required | ||
| 14 | Read fault memory, erase if necessary | |||
| 15 | Disconnect diagnostic system | AD00.00-P-2000-04A | ||