LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Mercedes Benz >> 2007 >> S550 Base >> Repair and Diagnosis (Single Page) >> Accessories & Equipment >> Cruise Control Systems >> Throttle Control, Speed Control Systems -- Basic Knowledge -- S-Class (221) >> Basic Knowledge >> Electronic accelerator pedal emergency running mode, function - GF30.20-P-4026MOS
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Electronic accelerator pedal emergency running mode, function - GF30.20-P-4026MOS

ENGINE 275.953 in MODEL 216.376, 221.176 as of Model Year 09 /AEJ 08 

ENGINE 275.982 in MODEL 216.379, 221.179 as of Model Year 09 /AEJ 08 

Electronic accelerator limp-home mode function requirements, general 

Limp-home mode electronic accelerator, general points 

The task of the electronic accelerator (EFP) limp-home mode consists in ensuring that the vehicle can be continued to be driven safely even if there are faults in the electronic accelerator system (EA).

Limp-home is recognizable from a significantly surging engine running characteristic.

The ME-SFI control unit (N3/10) controls limp-home mode according to the following sensors and signals:

Limp-home mode electronic accelerator function sequence 

The function sequence is described in the following steps:

Limp-home mode function sequence on failure of the accelerator pedal sensor 

If a Hall sensor fails, the system switches over to the second Hall sensor. The throttle valve opening is limited to about 60% of the maximum opening. In addition, the speed at the which the throttle valve opens is dynamically limited (throttle valve opens with a delay).

If the plausibility check is negative or if both Hall sensors fail, only idle speed is then still controlled.

Limp-home mode function sequence on failure of throttle valve actual value potentiometer 1 or 2 

If one potentiometer fails, the system switches over to the second, intact potentiometer. The air flow mass serves as a second parameter for comparative purposes.

If both potentiometers are faulty, the spring capsule brings the throttle valve to the limp-home position of about 10° opening angle.

Limp-home mode function sequence on failure of the throttle valve actuator motor 

The throttle valve actuator is de-energized and the spring capsule brings the throttle valve to the limp-home position of about 10° opening angle.

Limp-home position function sequence 

When the throttle valve IS in limp-home position, fuel is shut off/resupplied to the cylinders to limit engine speed to about 1200 to 1400 RPM at idle, and about 1800 in driving mode. If the brake pedal is operated, this always means idle speed input.

The ME-SFI control unit activates/deactivates the cylinders by switching the injection valves (Y62) on / off, according to:

IMPORTANT Diagnosis

Faults detected by the accelerator pedal sensor and throttle valve actuator are stored in the fault memory, and can be read out and deleted with the Diagnosis Assistance System (DAS).

REFER TO SYSTEM WIRING DIAGRAMS Function schematic for limp-home electronic accelerator Model 216 PE30.20-P-2051-97CAA
Model 221 PE30.20-P-2051-97SAA
  ME-SFI [ME] control unit, component description N3/10 GF07.61-P-6000MOS