Signal List For Logic Functions (Plc), PSM, Function - GF54.21-D-3032P
MODEL 906 with CODE ED5 (Parameterizable special module (PSM)) with CODE XM0 (Facelift)
MODEL 906 with CODE ED8 (Preinstallation for parameterizable special module (PSM)) with CODE XM0 (Facelift)
The programmable logic controller (SPS) described in the following is assumed to be as familiar. SPS means an electronic assembly which is used for control tasks and regulating tasks. Basically, a PLC is a device with specialized input and output interfaces. It uses these sensors and actuators to control, monitor and influence function processes.
| Signal name | Signal ID | Signal type | Signal default/comment |
|---|---|---|---|
| 10F8 PLC output: Group 1, logic block 1 | 10F8 | Bit | 0 |
| 10F9 PLC output: Group 1, logic block 1 INVERTED | 10F9 | Bit | 1 |
| 10FA PLC output: Group 1, logic block 2 | 10FA | Bit | 0 |
| 10FB PLC output: Group 1, logic block 2 INVERTED | 10FB | Bit | 1 |
| PLC output: Group 1, logic block 3 | 10FC | Bit | 0 |
| PLC output: Group 1, logic block 3 INVERTED | 10FD | Bit | 1 |
| PLC output: Group 1, logic block 4 | 10FE | Bit | 0 |
| PLC output: Group 1, logic block 4 INVERTED | 10Ff | Bit | 1 |
| PLC output: Group 1, flip-flop 1 | 3012 | Word | 0 0...65 535 |
| PLC output: Group 1, flip-flop 1 INVERTED | 1100 | Bit | 1 |
| PLC output: Group 1, flip-flop 2 | 3013 | Word | 0 0...65 535 |
| PLC output: Group 1, flip-flop 2 INVERTED | 1101 | Bit | 1 |
| PLC output: Group 1, timer | 1102 | Bit | 0 |
| PLC output: Group 1, timer INVERTED | 1103 | Bit | 1 |
| PLC output: Group 1, counter (counter reading) | 301C | Word | 0 0...65 535 |
| PLC output: Group 1, threshold switch "Threshold A" | 1104 | Bit | 0 |
| PLC output: Group 1, threshold switch "Threshold B" | 1105 | Bit | 0 |
| PLC output: Group 1, threshold switch "Threshold C" | 1106 | Bit | 0 |
| PLC output: Group 1, threshold switch "Threshold D" | 123B | Bit | 0 |
| PLC output: Group 1, hysteresis block | 1107 | Bit | 0 |
| PLC output: Group 1, hysteresis block INVERTED | 1108 | Bit | 1 |
| PLC output: Group 2, logic block 1 | 1109 | Bit | 0 |
| PLC output: Group 2, logic block 1 INVERTED | 110A | Bit | 1 |
| PLC output: Group 2, logic block 2 | 110B | Bit | 0 |
| PLC output: Group 2, logic block 2 INVERTED | 110C | Bit | 1 |
| PLC output: Group 2, logic block 3 | 110D | Bit | 0 |
| PLC output: Group 2, logic block 3 INVERTED | 110E | Bit | 1 |
| PLC output: Group 2, logic block 4 | 110F | Bit | 0 |
| PLC output: Group 2, logic block 4 INVERTED | 1110 | Bit | 1 |
| PLC output: Group 2, flip-flop 1 | 3014 | Word | 0 0...65 535 |
| PLC output: Group 2, flip-flop 1 INVERTED | 1111 | Bit | 1 |
| PLC output: Group 2, flip-flop 2 | 3015 | Word | 0 0...65 535 |
| PLC output: Group 2, flip-flop 2 INVERTED | 1112 | Bit | 1 |
| PLC output: Group 2, timer | 1113 | Bit | 0 |
| PLC output: Group 2, timer INVERTED | 1114 | Bit | 1 |
| PLC output: Group 2, counter (counter reading) | 301D | Word | 0 0...65 535 |
| PLC output: Group 2, threshold switch "Threshold A" | 1115 | Bit | 0 |
| PLC output: Group 2, threshold switch "Threshold B" | 1116 | Bit | 0 |
| PLC output: Group 2, threshold switch "Threshold C" | 1117 | Bit | 0 |
| PLC output: Group 2, threshold switch "Threshold D" | 123C | Bit | 0 |
| PLC output: Group 2, hysteresis block | 1118 | Bit | 0 |
| PLC output: Group 2, hysteresis block INVERTED | 1119 | Bit | 1 |
| PLC output: Group 3, logic block 1 | 111A | Bit | 0 |
| PLC output: Group 3, logic block 1 INVERTED | 111B | Bit | 1 |
| PLC output: Group 3, logic block 2 | 111C | Bit | 0 |
| PLC output: Group 3, logic block 2 INVERTED | 111D | Bit | 1 |
| PLC output: Group 3, logic block 3 | 111E | Bit | 0 |
| PLC output: Group 3, logic block 3 INVERTED | 111F | Bit | 1 |
| PLC output: Group 3, logic block 4 | 1120 | Bit | 0 |
| PLC output: Group 3, logic block 4 INVERTED | 1121 | Bit | 1 |
| PLC output: Group 3, flip-flop 1 | 3016 | Word | 0 0...65 535 |
| PLC output: Group 3, flip-flop 1 INVERTED | 1122 | Bit | 1 |
| PLC output: Group 3, flip-flop 2 | 3017 | Word | 0 0...65 535 |
| PLC output: Group 3, flip-flop 2 INVERTED | 1123 | Bit | 1 |
| PLC output: Group 3, timer | 1124 | Bit | 0 |
| PLC output: Group 3, timer INVERTED | 1125 | Bit | 1 |
| PLC output: Group 3, counter (counter reading) | 301E | Word | 0 0...65 535 |
| PLC output: Group 3, threshold switch "Threshold A" | 1126 | Bit | 0 |
| PLC output: Group 3, threshold switch "Threshold B" | 1127 | Bit | 0 |
| PLC output: Group 3, threshold switch "Threshold C" | 1128 | Bit | 0 |
| PLC output: Group 3, threshold switch "Threshold D" | 123D | Bit | 0 |
| PLC output: Group 3, hysteresis block | 1129 | Bit | 0 |
| PLC output: Group 3, hysteresis block INVERTED | 112A | Bit | 1 |
| PLC output: Group 4, logic block 1 | 112B | Bit | 0 |
| PLC output: Group 4, logic block 1 INVERTED | 112C | Bit | 1 |
| PLC output: Group 4, logic block 2 | 112D | Bit | 0 |
| PLC output: Group 4, logic block 2 INVERTED | 112E | Bit | 1 |
| PLC output: Group 4, logic block 3 | 112F | Bit | 0 |
| PLC output: Group 4, logic block 3 INVERTED | 1130 | Bit | 1 |
| PLC output: Group 4, logic block 4 | 1131 | Bit | 0 |
| PLC output: Group 4, logic block 4 INVERTED | 1132 | Bit | 1 |
| PLC output: Group 4, flip-flop 1 | 3018 | Word | 0 0...65 535 |
| PLC output: Group 4, flip-flop 1 INVERTED | 1133 | Bit | 1 |
| PLC output: Group 4, flip-flop 2 | 3019 | Word | 0 0...65 535 |
| PLC output: Group 4, flip-flop 2 INVERTED | 1134 | Bit | 1 |
| PLC output: Group 4, timer | 1135 | Bit | 0 |
| PLC output: Group 4, timer INVERTED | 1136 | Bit | 1 |
| PLC output: Group 4, counter (counter reading) | 301F | Word | 0 0...65 535 |
| PLC output: Group 4, threshold switch "Threshold A" | 1137 | Bit | 0 |
| PLC output: Group 4, threshold switch "Threshold B" | 1138 | Bit | 0 |
| PLC output: Group 4, threshold switch "Threshold C" | 1139 | Bit | 0 |
| PLC output: Group 4, threshold switch "Threshold D" | 123E | Bit | 0 |
| PLC output: Group 4, hysteresis block | 113A | Bit | 0 |
| PLC output: Group 4, hysteresis block INVERTED | 113B | Bit | 1 |
| PLC output: Group 5, logic block 1 | 1276 | Bit | 0 |
| PLC output: Group 5, logic block 1 INVERTED | 1277 | Bit | 1 |
| PLC output: Group 5, logic block 2 | 1278 | Bit | 0 |
| PLC output: Group 5, logic block 2 INVERTED | 1279 | Bit | 1 |
| PLC output: Group 5, logic block 3 | 127A | Bit | 0 |
| PLC output: Group 5, logic block 3 INVERTED | 127B | Bit | 1 |
| PLC output: Group 5, logic block 4 | 127C | Bit | 0 |
| PLC output: Group 5, logic block 4 INVERTED | 127D | Bit | 1 |
| PLC output: Group 5, flip-flop 1 INVERTED | 127E | Bit | 1 |
| PLC output: Group 5, flip-flop 2 INVERTED | 127F | Bit | 1 |
| PLC output: Group 5, timer | 1280 | Bit | 0 |
| PLC output: Group 5, timer INVERTED | 1281 | Bit | 1 |
| PLC output: Group 5, threshold switch "Threshold A" | 1282 | Bit | 0 |
| PLC output: Group 5, threshold switch "Threshold B" | 1283 | Bit | 0 |
| PLC output: Group 5, threshold switch "Threshold C" | 1284 | Bit | 0 |
| PLC output: Group 5, hysteresis block | 1286 | Bit | 0 |
| PLC output: Group 5, hysteresis block INVERTED | 1287 | Bit | 1 |
| PLC output: Group 6, logic block 1 | 1288 | Bit | 0 |
| PLC output: Group 6, logic block 1 INVERTED | 1289 | Bit | 1 |
| PLC output: Group 6, logic block 2 | 128A | Bit | 0 |
| PLC output: Group 6, logic block 2 INVERTED | 128B | Bit | 1 |
| PLC output: Group 6, logic block 3 | 128C | Bit | 0 |
| PLC output: Group 6, logic block 3 INVERTED | 128D | Bit | 1 |
| PLC output: Group 6, logic block 4 | 128E | Bit | 0 |
| PLC output: Group 6, logic block 4 INVERTED | 128F | Bit | 1 |
| PLC output: Group 6, flip-flop 1 INVERTED | 1290 | Bit | 1 |
| PLC output: Group 6, flip-flop 2 INVERTED | 1291 | Bit | 1 |
| PLC output: Group 6, timer | 1292 | Bit | 0 |
| PLC output: Group 6, timer INVERTED | 1293 | Bit | 1 |
| PLC output: Group 6, threshold switch "Threshold A" | 1294 | Bit | 0 |
| PLC output: Group 6, threshold switch "Threshold B" | 1295 | Bit | 0 |
| PLC output: Group 6, threshold switch "Threshold C" | 1296 | Bit | 0 |
| PLC output: Group 6, hysteresis block | 1298 | Bit | 0 |
| PLC output: Group 6, hysteresis block INVERTED | 1299 | Bit | 1 |
| PLC output: Group 7, logic block 1 | 129A | Bit | 0 |
| PLC output: Group 7, logic block 1 INVERTED | 129B | Bit | 1 |
| PLC output: Group 7, logic block 2 | 129C | Bit | 0 |
| PLC output: Group 7, logic block 2 INVERTED | 129D | Bit | 1 |
| PLC output: Group 7, logic block 3 | 129E | Bit | 0 |
| PLC output: Group 7, logic block 3 INVERTED | 129F | Bit | 1 |
| PLC output: Group 7, logic block 4 | 12A0 | Bit | 0 |
| PLC output: Group 7, logic block 4 INVERTED | 12A1 | Bit | 1 |
| PLC output: Group 7, flip-flop 1 INVERTED | 1242 | Bit | 1 |
| PLC output: Group 7, flip-flop 2 INVERTED | 1243 | Bit | 1 |
| PLC output: Group 7, timer | 12A4 | Bit | 0 |
| PLC output: Group 7, timer INVERTED | 12A5 | Bit | 1 |
| PLC output: Group 7, threshold switch "Threshold A" | 12A6 | Bit | 0 |
| PLC output: Group 7, threshold switch "Threshold B" | 12A7 | Bit | 0 |
| PLC output: Group 7, threshold switch "Threshold C" | 12A8 | Bit | 0 |
| PLC output: Group 7, hysteresis block | 12AA | Bit | 0 |
| PLC output: Group 7, hysteresis block INVERTED | 12AB | Bit | 1 |
| PLC output: Group 8, logic block 1 | 12AC | Bit | 0 |
| PLC output: Group 8, logic block 1 INVERTED | 12AD | Bit | 1 |
| PLC output: Group 8, logic block 2 | 12AE | Bit | 0 |
| PLC output: Group 8, logic block 2 INVERTED | 12Af | Bit | 1 |
| PLC output: Group 8, logic block 3 | 12B0 | Bit | 0 |
| PLC output: Group 8, logic block 3 INVERTED | 12B1 | Bit | 1 |
| PLC output: Group 8, logic block 4 | 12B2 | Bit | 0 |
| PLC output: Group 8, logic block 4 INVERTED | 12B3 | Bit | 1 |
| PLC output: Group 8, flip-flop 1 INVERTED | 12B4 | Bit | 1 |
| PLC output: Group 8, flip-flop 2 INVERTED | 12B5 | Bit | 1 |
| PLC output: Group 8, timer | 12B6 | Bit | 0 |
| PLC output: Group 8, timer INVERTED | 12B7 | Bit | 1 |
| PLC output: Group 8, threshold switch "Threshold A" | 12B8 | Bit | 0 |
| PLC output: Group 8, threshold switch "Threshold B" | 12B9 | Bit | 0 |
| PLC output: Group 8, threshold switch "Threshold C" | 12BA | Bit | 0 |
| PLC output: Group 8, hysteresis block | 12BC | Bit | 0 |
| PLC output: Group 8, hysteresis block INVERTED | 12BD | Bit | 1 |