LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Mercedes Benz >> 2012 >> Sprinter 2500, Van Cargo Extended >> Repair and Diagnosis >> Accessories & Equipment >> Communication Devices >> Electrical System, Equipment & Instructions - Basic Knowledge Part 3 - Model 906 >> Basic Knowledge >> Signal List For Working Functions, PSM, Function - GF54.21-D-3035P
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Signal List For Working Functions, PSM, Function - GF54.21-D-3035P

MODEL 906 with CODE ED5 (Parameterizable special module (PSM)) with CODE XM0 (Facelift) Working speed control 

MODEL 906 with CODE ED5 (Parameterizable special module (PSM)) with CODE XM0 (Facelift) Speed limit (GB) 

MODEL 906 with CODE ED5 (Parameterizable special module (PSM)) with CODE XM0 (Facelift) Engine start/stop (MSS) 

MODEL 906 with CODE ED5 (Parameterizable special module (PSM)) with CODE XM0 (Facelift) Power take-off (PTO) 

MODEL 906 with CODE ED8 (Preinstallation for parameterizable special module (PSM)) with CODE XM0 (Facelift) Working speed control 

MODEL 906 with CODE ED8 (Preinstallation for parameterizable special module (PSM)) with CODE XM0 (Facelift) Speed limit (GB) 

MODEL 906 with CODE ED8 (Preinstallation for parameterizable special module (PSM)) with CODE XM0 (Facelift) Engine start/stop (MSS) 

MODEL 906 with CODE ED8 (Preinstallation for parameterizable special module (PSM)) with CODE XM0 (Facelift) Power take-off (PTO) 

WORKING SPEED CONTROL

Signal name Signal ID Signal type Signal default/comment
Lockout of accelerator pedal (module "Working speed control") 10E8 Bit 0
Enabling of working speed control 10E9 Bit 0
Switch "Rpm change" OPERATED (module "Rpm change") 10EA Bit 0
Enabling of fixed speed 10EB Bit 0
Status of solenoid valve actuation (module "Power take-off") 10EC Bit 0
Ramp mode ACTIVE (otherwise pulse mode) 10F0 Bit 0
Current maximum speed ("rpm limit" module) 2026 Byte 0
Value range/conversion 0... 254 = 254 km/h
Specified value of rpm (module "Rpm change") 300C Word 0
Value range/conversion of rpm specified value which is output via Controller Area Network bus class B (interior CAN B)
Current maximum rpm limit ("rpm limit" module) 300D Word 0
Value range/conversion 0... 8000 = 8000 rpm
Current minimum rpm limit ("rpm limit" module) 300E Word 0
Value range/conversion 0... 8000 = 8000 rpm
Current maximum torque ("rpm limit" module) 300F Word 0
Value range/conversion 0... 254 = 254 Nm
Specified value of rpm (module "Fixed speed") 3010 Word 0
Value range/conversion 0... 8000 = 8000 rpm
Specified value of rpm (module "Hand throttle actuator") 3011 Word 0
Value range/conversion 0... 8000 = 8000 rpm
POWER TAKE-OFF (PTO)

Signal name Signal ID Signal type Signal default/comment
Request for working speed control (module "Power take-off") 10ED Bit 0
Switch on indicator lamp (module "Power take-off") 10EE Bit 0
Actuate solenoid valve for power take-off (module "Power take-off") 10Ef Bit 0
Power take-off ENGAGED 1241 Bit 0
ENGINE START/STOP (MSS)

Signal name Signal ID Signal type Signal default/comment
Signal "Engine start" 10F6 Bit 0
Signal "Engine stop" 10F7 Bit 0
SPEED LIMIT (GB)

Signal name Signal ID Signal type Signal default/comment
Speed limit 2028 Byte 0
Value range/conversion 0... 254 = 254 km/h
Parameterizable special module (PSM) control unit component description GF54.21-D-5005P