Can Matrix, PSM, Function - GF54.21-D-3038PC
MODEL 906 with CODE ED5 (Parameterizable special module (PSM)) with CODE XM0 (Facelift) Incoming CAN signals, ISO 11992-2/3
MODEL 906 with CODE ED8 (Preinstallation for parameterizable special module (PSM)) with CODE XM0 (Facelift) Incoming CAN signals, ISO 11992-2/3
| ID | ID-Name | Cycle time in ms | Launch type | Signal byte no. | Signal bit no. | Signal name | Signal function | Signal length (Bit) | Signal default | Signal not available | Normalization | Value range (phys.) |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 0C FE 60 C9 h | ISO11 992 G PM23 | 100 | cyclic | 1 | 0 | Req Engine Speed | - | 16 | FFFFh | FFFFh | 0... 64 255 | 0...8031.875 rpm |
| 3 | 0 | Req Engine Speed Upper Lim | - | 16 | FFFFh | FFFFh | 0... 64 255 | 0...8031.875 rpm | ||||
| 5 | 0 | Req Engine Speed Lower Lim | - | 16 | FFFFh | FFFFh | 0... 64 255 | 0...8031.875 rpm | ||||
| 7 | 0 | Req Engine Torque Limit | - | 8 | FFh | FFh | 0... 250 | -125... +125 | ||||
| 8 | 0 | Req Engine Speed Limit | - | 8 | FFh | FFh | 0... 250 | 0...250 km/h | ||||
| 0C FE 62 C9 h | ISO11 992 G PM24 | 100 | cyclic | 1 | 0 | - | - | 8 | FFh | - | ||
| 2 | 0 | Starter Lockout Switch | - | 2 | 3h | 3h | B1/B0 = Function 00B = Switched off/OFF 01B = Switched on/ON 11B = Signal not available/SNA |
|||||
| 2 | 2 | Engine Start Switch | - | 2 | 3h | 3h | B1/B0 = Function 00B = Switched off/OFF 01B = Switched on/ON 11B = Signal not available/SNA |
|||||
| 2 | 4 | Engine Stop Switch | - | 2 | 3h | 3h | B1/B0 = Function 00B = Switched off/OFF 01B = Switched on/ON 11B = Signal not available/SNA |
|||||
| 2 | 6 | - | - | 2 | 3h | - | ||||||
| 3 | 0 | Refuse Packer Step Switch | - | 2 | 3h | 3h | B1/B0 = Function 00B = Switched off/OFF 01B = Switched on/ON 11B = Signal not available/SNA |
|||||
| 3 | 2 | Operating Panel Active | - | 2 | 3h | 3h | B1/B0 = Function 00B = Operating panel not active/NOTACT 01B = Operating panel active/ACT 11B = Signal not available/SNA |
|||||
| 3 | 4 | - | - | 2 | 3h | - | ||||||
| 3 | 6 | First Clutch DPdtPTO Switch | - | 2 | 3h | 3h | B1/B0 = Function 00B = Switched off/OFF 01B = Switched on/ON 11B = Signal not available/SNA |
|||||
| 4 | 0 | - | - | 2 | 3h | - | ||||||
| 4 | 2 | Clutch IndpdtPTO Switch | - | 2 | 3h | 3h | B1/B0 = Function 00B = Switched off/OFF 01B = Switched on/ON 11B = Signal not available/SNA |
|||||
| 4 | 4 | First Engine MtdPTO Switch | - | 2 | 3h | 3h | B1/B0 = Function 00B = Switched off/OFF 01B = Switched on/ON 11B = Signal not available/SNA |
|||||
| 4 | 6 | - | - | 2 | 3h | - | ||||||
| 5 | 0 | - | - | 8 | FFh | - | ||||||
| 6 | 0 | - | - | 8 | FFh | - | ||||||
| 7 | 0 | - | - | 8 | FFh | - | ||||||
| 8 | 0 | - | - | 8 | FFh | - | ||||||
| 18 EF 10 C9 h | ISO11 992 G PM2A | 100 | cyclic | 1 | 0 | PTO Governor Engine Speed Mode Switch | - | 2 | 3h | 3h | B1/B0 = Function 00B = Switched off/OFF 01B = Switched on/ON 10B = Error indicator/ERROR 11B = Signal not available/SNA |
|
| 1 | 2 | Fixed Engine Speed 1 | - | 2 | 3h | 3h | B1/B0 = Function 00B = Turned off/OFF 01B = Turned on/ON 10B = Error indicator/ERROR 11B = Signal not available/SNA |
|||||
| 1 | 4 | Fixed Engine Speed 2 | - | 2 | 3h | 3h | B1/B0 = Function 00B = Turned off/OFF 01B = Turned on/ON 10B = Error indicator/ERROR 11B = Signal not available/SNA |
|||||
| 1 | 6 | Fixed Engine Speed 3 | - | 2 | 3h | 3h | B1/B0 = Function 00B = Turned off/OFF 01B = Turned on/ON 10B = Error indicator/ERROR 11B = Signal not available/SNA |
|||||
| 2 | 0 | Engine Speed Control States | - | 3 | 3h | 7h | B2/B1/B0 = Function 000B = Off/Disabled/OFF 001B = Resume/RESUME 010B = Increase/INCREASE 011B = Decrease/DECREASE 110B = Error indicator/ERROR 111B = Signal not available/SNA |
|||||
| 2 | 3 | - | - | 5 | 1Fh | - | ||||||
| 3 | 0 | Speed Control Mode Upper Limit 1 | - | 2 | 3h | 3h | B1/B0 = Function 00B = Turned off/OFF 01B = Turned on/ON 10B = Error indicator/ERROR 11B = Signal not available/SNA |
|||||
| 3 | 2 | Speed Control Mode Upper Limit 2 | - | 2 | 3h | 3h | B1/B0 = Function 00B = Turned off/OFF 01B = Turned on/ON 10B = Error indicator/ERROR 11B = Signal not available/SNA |
|||||
| 3 | 4 | Speed Control Mode Upper Limit 3 | - | 2 | 3h | 3h | B1/B0 = Function 00B = Turned off/OFF 01B = Turned on/ON 10B = Error indicator/ERROR 11B = Signal not available/SNA |
|||||
| 3 | 6 | - | - | 2 | 3h | - | ||||||
| 4 | 0 | Warning Buzzer | - | 2 | 3h | 3h | B1/B0 = Function 00B = Turned off/OFF 01B = Turned on/ON 10B = Error indicator/ERROR 11B = Signal not available/SNA |
|||||
| 4 | 2 | - | - | 6 | 3Fh | - | ||||||
| 5 | 0 | Go To Neutral | - | 2 | 3h | 3h | B1/B0 = Function 00B = Turned off/OFF 01B = Turned on/ON 10B = Error indicator/ERROR 11B = Signal not available/SNA |
|||||
| 5 | 2 | - | - | 6 | 3Fh | - | ||||||
| 6 | 0 | - | - | 8 | FFh | - | ||||||
| 7 | 0 | - | - | 8 | FFh | - | ||||||
| 8 | 0 | - | - | 8 | FFh | - |
| Parameterizable special module (PSM) control unit component description | GF54.21-D-5005P |