PSM Can Matrix, Function - GF54.21-D-3038HC

MODEL 906 with CODE (ED5) Parameterizable special module (PSM) Incoming CAN signals, ISO 11992-2/3 

MODEL 906 with CODE (ED8) Preinstallation for parameterizable special module (PSM) Incoming CAN signals, ISO 11992-2/3 

ID ID-Name Cycle time in ms Launch type Signal Byte No. Signal Bit No. Signal name Signal function Signal length (Bit) Signal default Signal not available Normaliza tion Value range (phys.)
0CF E60 C9h ISO11 992 G PM23 100 cyclic 1 0 Req Engine Speed - 16 FFFFh FFFFh 0...64 255 0...8031, 875 rpm
        3 0 Req Engine Speed Upper Lim - 16 FFFFh FFFFh 0...64 255 0...8031, 875 rpm
        5 0 Req Engine Speed Lower Lim - 16 FFFFh FFFFh 0...64 255 0...8031, 875 rpm
        7 0 Req Engine Torque Limit - 8 FFh FFh 0...250 -125...+125
        8 0 Req Engine Speed Limit - 8 FFh FFh 0...250 0...250 km/h
0CF E62 C9h ISO11 992_G PM24 100 cyclic 1 0 - - 8 FFh -    
        2 0 Starter Lockout Switch - 2 3h 3h   B1/B0 = Function 
00B = Switched off/OFF
01B = Switched on/ON
11B = Signal not available/SNA
        2 2 Engine Start Switch - 2 3h 3h   B1/B0 = Function 
00B = Switched off/OFF
01B = Switched on/ON
11B = Signal not available/SNA
        2 4 Engine Stop Switch - 2 3h 3h   B1/B0 = Function 
00B = Switched off/OFF
01B = Switched on/ON
11B = Signal not available/SNA
        2 6 - - 2 3h -    
        3 0 Refuse Pakker Step Switch - 2 3h 3h   B1/B0 = Function 
00B = Switched off/OFF
01B = Switched on/ON
11B = Signal not available/SNA
        3 2 Operating Panel Active - 2 3h 3h   B1/B0 = Function 
00B = Operating panel not active/NOTACT
01B = Operating panel active/ACT
11B = Signal not available/SNA
        3 4 - - 2 3h -    
        3 6 First Clutch DPdtPTO Switch - 2 3h 3h   B1/B0 = Function 
00B = Switched off/OFF
01B = Switched on/ON
11B = Signal not available/SNA
        4 0 - - 2 3h -    
        4 2 Clutch IndpdtPTO Switch - 2 3h 3h   B1/B0 = Function 
00B = Switched off/OFF
01B = Switched on/ON
11B = Signal not available/SNA
        4 4 First Engine MtdPTO Switch - 2 3h 3h   B1/B0 = Function 
00B = Switched off/OFF
01B = Switched on/ON
11B = Signal not available/SNA
        4 6 - - 2 3h -    
        5 0 - - 8 FFh -    
        6 0 - - 8 FFh -    
        7 0 - - 8 FFh -    
        8 0 - - 8 FFh -    
18E F10 C9h ISO11 992_G PM2A 100 cyclic 1 0 PTO Governor Engine Speed Mode Switch - 2 3h 3h   B1/B0 = Function 
00B = Switched off/OFF
01B = Switched on/ON
10B = Error indicator/ERROR
11B = Signal not available/SNA
        1 2 Fixed Engine Speed 1 - 2 3h 3h   B1/B0 = Function 
00B = Turned off/OFF
01B = Turned on/ON
10B = Error Indicator/ERROR
11B = Signal not available/SNA
        1 4 Fixed Engine Speed 2 - 2 3h 3h   B1/B0 = Function 
00B = Turned off/OFF
01B = Turned on/ON
10B = Error Indicator/ERROR
11B = Signal not available/SNA
        1 6 Fixed Engine Speed 3 - 2 3h 3h   B1/B0 = Function 
00B = Turned off/OFF
01B = Turned on/ON
10B = Error Indicator/ERROR
11B = Signal not available/SNA
        2 0 Engine Speed Control States - 3 3h 7h   B2/B1/B0 = Function 
000B = Off/Disabled/OFF
001B = Resume/RESUME
010B = Increase/INCREASE 011B = Decrease/DECREASE
110B = Error Indicator/ERROR
111B = Signal not available/SNA
        2 3 - - 5 1Fh -    
        3 0 Speed Control Mode Upper Limit 1 - 2 3h 3h   B1/B0 = Function 
00B = Turned off/OFF
01B = Turned on/ON
10B = Error Indicator/ERROR
11B = Signal not available/SNA
        3 2 Speed Control Mode Upper Limit 2 - 2 3h 3h   B1/B0 = Function 
00B = Turned off/OFF
01B = Turned on/ON
10B = Error Indicator/ERROR
11B = Signal not available/SNA
        3 4 Speed Control Mode Upper Limit 3 - 2 3h 3h   B1/B0 = Function 
00B = Turned off/OFF
01B = Turned on/ON
10B = Error Indicator/ERROR
11B = Signal not available/SNA
        3 6 - - 2 3h -    
        4 0 Warning Buzzer - 2 3h 3h   B1/B0 = Function 
00B = Turned off/OFF
01B = Turned on/ON
10B = Error Indicator/ERROR
11B = Signal not available/SNA
        4 2 - - 6 3Fh -    
        5 0 Go To Neutral - 2 3h 3h   B1/B0 = Function 
00B = Turned off/OFF
01B = Turned on/ON
10B = Error Indicator/ERROR
11B = Signal not available/SNA
        5 2 - - 6 3Fh -    
        6 0 - - 8 FFh -    
        7 0 - - 8 FFh -    
        8 0 - - 8 FFh -    
Parameterizable special module (PSM) control unit component description GF54.21-D-5005H