Signal List For Working Functions, PSM, Function - GF54.21-D-3035H
MODEL 906 with CODE (ED5) Parameterizable special module (PSM) working speed control
MODEL 906 with CODE (ED5) Parameterizable special module (PSM) power take-off (PTO)
MODEL 906 with CODE (ED5) Parameterizable special module (PSM) Speed limit (GB)
MODEL 906 with CODE (ED5) Parameterizable special module (PSM) Engine start/stop (MSS)
MODEL 906 with CODE (ED8) Preinstallation for parameterizable special module (PSM) working speed control
MODEL 906 with CODE (ED8) Preinstallation for parameterizable special module (PSM) power take-off (PTO)
MODEL 906 with CODE (ED8) Preinstallation for parameterizable special module (PSM) Speed limit (GB)
MODEL 906 with CODE (ED8) Preinstallation for parameterizable special module (PSM) Engine start/stop (MSS)
| Signal name | Signal ID | Signal type | Signal default/comment |
|---|---|---|---|
| Accelerator pedal lock ("working speed control" module) | 10E8 | Bit | 0 |
| Enabling of working speed control | 10E9 | Bit | 0 |
| rpm change switch pressed ("rpm change" module) | 10EA | Bit | 0 |
| Enabling of fixed speed | 10EB | Bit | 0 |
| Status of solenoid valve actuation ("power take-off" module) | 10EC | Bit | 0 |
| Ramp mode active (otherwise pulse mode) | 10F0 | Bit | 0 |
| Current maximum speed ("rpm limit" module) | 2026 | Byte | 0 Value range/conversion 0...254 = 254 km/h |
| Specified value of rpm ("rpm change" module) | 300C | Word | 0 Value range/conversion of rpm specified value which is output via Controller Area Network bus class B (interior) (CAN B) |
| Current maximum rpm limit ("rpm limit" module) | 300D | Word | 0 Value range/conversion 0...8000 = 8000 rpm |
| Current minimum rpm limit ("rpm limit" module) | 300E | Word | 0 Value range/conversion 0...8000 = 8000 rpm |
| Current maximum torque ("rpm limit" module) | 300F | Word | 0 Value range/conversion 0...254 = 254 Nm |
| Specified value of rpm ("fixed speed" module) | 3010 | Word | 0 Value range/conversion 0...8000 = 8000 rpm |
| Specified value of rpm ("hand throttle actuator" module) | 3011 | Word | 0 Value range/conversion 0...8000 = 8000 rpm |
| Signal name | Signal ID | Signal type | Signal default/comment |
|---|---|---|---|
| Request request for working speed control ("power take-off" module) | 10 ED | Bit | 0 |
| Switch on indicator lamp ("power take-off") | 10EE | Bit | 0 |
| Actuate solenoid valve for power take-off ("power take-off" module) | 10 EF | Bit | 0 |
| PTO engaged | 1241 | Bit | 0 |
| Signal name | Signal ID | Signal type | Signal default/comment |
|---|---|---|---|
| Signal "Engine start" | 10F6 | Bit | 0 |
| Signal "Engine stop" | 10F7 | Bit | 0 |
| Signal name | Signal ID | Signal type | Signal default/comment |
|---|---|---|---|
| Vehicle speed limit | 2028 | Byte | 0 Value range/conversion 0...254 = 254 km/h |
| Parameterizable special module (PSM) control unit component description | GF54.21-D-5005H |