ADBLUE Controls DTCS (SCRCM)
ADBLUE CONTROLS DTCS (SCRCM)
| MB DTC | Description |
|---|---|
| 000100 | The quantity control valve has an electrical fault or an open circuit. |
| 007108 | CAN message 'Ambient temperature' is faulty. |
| 007109 | CAN message 'Ambient temperature' is faulty. |
| 007121 | 007121 |
| 007122 | 007122 |
| 007129 | CAN message 'Ambient temperature' is faulty. |
| 007164 | The outside temperature sensor has a malfunction. There is an implausible signal. |
| 007216 | The outside temperature sensor has a short circuit to ground. The limit value for electrical voltage has not been attained. |
| 007221 | CAN message 'Ambient temperature' is faulty. |
| 007317 | The outside temperature sensor has a short circuit to positive. The limit value for electrical voltage has been exceeded. |
| 007322 | CAN message 'Ambient temperature' is faulty. |
| 056201 | The battery voltage is too low. |
| 056216 | The battery voltage is too low. |
| 05621C | The battery voltage is too low. |
| 056300 | The battery voltage is too high. |
| 056317 | The battery voltage is too high. |
| 05631C | The battery voltage is too high. |
| 060704 | 060704 |
| 06071F | 06071F |
| 060725 | Control unit 'N118/5 (AdBlue® control unit)' has a malfunction. There is a faulty signal waveform. |
| 060729 | Control unit 'N118/5 (AdBlue® control unit)' has a malfunction. There is an invalid signal. |
| 060747 | Control unit 'N118/5 (AdBlue® control unit)' has a malfunction. There is an invalid signal. |
| 060749 | Control unit 'N118/5 (AdBlue® control unit)' has a malfunction. There is an internal electrical fault. |
| 06074B | Control unit 'N118/5 (AdBlue® control unit)' has a malfunction. |
| 060761 | Control unit 'N118/5 (AdBlue® control unit)' has a malfunction. The signal calculation is faulty. |
| 060763 | Control unit 'N118/5 (AdBlue® control unit)' has a malfunction. |
| 060764 | The control unit has a malfunction. There is an implausible signal. |
| 060781 | The control unit has a malfunction. Incorrect data were received. |
| 060782 | Control unit 'N118/5 (AdBlue® control unit)' has a malfunction. Hardware fault |
| 060786 | Control unit 'N118/5 (AdBlue® control unit)' has a malfunction. There is an invalid signal. |
| 060792 | Control unit 'N118/5 (AdBlue® control unit)' has a malfunction. |
| 060796 | Control unit 'N118/5 (AdBlue® control unit)' has a malfunction. There is an internal component fault. |
| 060B49 | There is an internal control unit fault in the analog/digital converter. |
| 060B63 | There is an internal control unit fault in the analog/digital converter. |
| 060B64 | An internal control unit fault is present in the digital/digital converter. |
| 060B92 | An internal control unit fault is present in the digital/digital converter. |
| 061042 | The coding of the control unit is incorrect. |
| 061043 | The coding of the control unit is incorrect. |
| 061048 | The coding of the control unit is incorrect. |
| 062F41 | There is an internal error in the EEPROM of the control unit. There is a general checksum error. |
| 062F42 | There is an internal error in the EEPROM of the control unit. |
| 062F43 | There is an internal error in the EEPROM of the control unit. |
| 062F44 | There is an internal error in the EEPROM of the control unit. There is an error in the data memory. |
| 062F46 | There is an internal error in the EEPROM of the control unit. There is an error in the calibration or parameterization memory. |
| 062F48 | There is an internal error in the EEPROM of the control unit. |
| 06431C | Output 1 for the reference voltage of the sensors has a short circuit to positive. The voltage value is outside the permissible range. |
| 06531C | Output 2 for the power supply of the sensors has a short circuit to positive. |
| 066821 | The internal temperature sensor of the control unit has a short circuit to ground. |
| 066922 | The internal temperature sensor of the control unit has a short circuit to positive. |
| 06991C | Output 3 for the reference voltage of the sensors has a short circuit to positive. |
| 06B116 | Power supply of sensors |
| 06B217 | Power supply of sensors |
| 13DF00 | The AdBlue® system has a malfunction. |
| 16141F | An internal control unit reset was performed. |
| 161447 | An internal control unit reset was performed. |
| 161464 | An internal control unit reset was performed. |
| 202A00 | The heating of the AdBlue® tank module has an electrical fault or an open circuit. |
| 202A01 | The heating of the AdBlue® tank module has an electrical fault or an open circuit. |
| 202B11 | The heating of the AdBlue® tank module has a short circuit to ground. |
| 202B16 | The heating of the AdBlue® tank module has a short circuit to ground. |
| 202C12 | The heating of the AdBlue® tank module has a short circuit to positive. |
| 202C17 | The heating of the AdBlue® tank module has a short circuit to positive. |
| 202D29 | The AdBlue® tank is empty. |
| 202E4B | AdBlue® metering valve 1 (cylinder bank 1) has a malfunction. |
| 202E71 | AdBlue® metering valve 1 (cylinder bank 1) has a malfunction. The actuator is blocked. |
| 202E73 | The AdBlue® consumption is too low. |
| 202E98 | AdBlue® metering valve 1 (cylinder bank 1) has a malfunction. |
| 202F00 | The output for the AdBlue® supply has a malfunction. |
| 203200 | Component 'B16/15 (Temperature sensor upstream of SCR catalytic converter)' has a short circuit to ground. |
| 203300 | Component 'B16/15 (Temperature sensor upstream of SCR catalytic converter)' has a short circuit to positive. |
| 203A13 | The AdBlue® fill level sensor has an electrical fault. |
| 203B09 | The AdBlue® fill level sensor has an electrical fault. |
| 203B21 | The AdBlue® fill level sensor has a malfunction. |
| 203B22 | The AdBlue® fill level sensor has a malfunction. |
| 203B29 | The AdBlue® fill level sensor has a malfunction. |
| 203B64 | The AdBlue® fill level sensor has a malfunction. There is an implausible signal. |
| 203B84 | The AdBlue® fill level sensor has an electrical fault. |
| 203B85 | The AdBlue® fill level sensor has an electrical fault. |
| 203B86 | The AdBlue® fill level sensor has a malfunction. |
| 203C11 | The AdBlue® fill level sensor has a short circuit to ground. |
| 203C16 | The AdBlue® fill level sensor has a short circuit to ground. |
| 203C21 | The AdBlue® fill level sensor has a short circuit to ground. |
| 203C23 | The AdBlue® fill level sensor has an electrical fault. |
| 203C84 | The AdBlue® fill level sensor has a short circuit to ground. |
| 203D12 | The AdBlue® fill level sensor has a short circuit to positive. |
| 203D17 | The AdBlue® fill level sensor has a short circuit to positive. |
| 203D22 | The AdBlue® fill level sensor has a short circuit to positive. |
| 203D24 | The AdBlue® fill level sensor has an electrical fault. |
| 203D85 | The AdBlue® fill level sensor has a short circuit to positive. |
| 203F29 | The AdBlue® tank is empty. |
| 204321 | Component 'A103/1b1 (AdBlue® tank temperature sensor)' has an electrical fault or an open circuit. |
| 204322 | Component 'A103/1b1 (AdBlue® tank temperature sensor)' has an electrical fault or an open circuit. |
| 204400 | Component 'A103/1b1 (AdBlue® tank temperature sensor)' has an electrical fault or an open circuit. |
| 204500 | Component 'A103/1b1 (AdBlue® tank temperature sensor)' has an electrical fault or an open circuit. |
| 204713 | AdBlue® metering valve 1 (cylinder bank 1) has an electrical fault or an open circuit. |
| 204801 | AdBlue® metering valve 1 (cylinder bank 1) has a short circuit to ground. |
| 204811 | AdBlue® metering valve 1 (cylinder bank 1) has a short circuit to ground. |
| 204901 | AdBlue® metering valve 1 (cylinder bank 1) has a short circuit to positive. |
| 204912 | AdBlue® metering valve 1 (cylinder bank 1) has a short circuit to positive. |
| 204B21 | Component 'A103/2b1 (AdBlue® pressure sensor)' has an electrical fault or an open circuit. |
| 204B22 | Component 'A103/2b1 (AdBlue® pressure sensor)' has an electrical fault or an open circuit. |
| 204B62 | Component 'A103/2b1 (AdBlue® pressure sensor)' has an electrical fault or an open circuit. |
| 204B64 | Component 'A103/2b1 (AdBlue® pressure sensor)' has an electrical fault or an open circuit. |
| 204C16 | The AdBlue® pressure sensor has a short circuit to ground. |
| 204C21 | The AdBlue® pressure sensor has a short circuit to ground. |
| 204D17 | The AdBlue® pressure sensor has a short circuit to positive. |
| 204D22 | The signal of component 'A103/2b1 (AdBlue® pressure sensor)' is implausible. |
| 204F00 | General system error |
| 205B00 | The temperature sensor 'AdBlue® tank' has a malfunction. |
| 205B21 | The temperature sensor 'AdBlue® tank' has a malfunction. |
| 205B22 | The temperature sensor 'AdBlue® tank' has a malfunction. |
| 205B28 | The temperature sensor 'AdBlue® tank' has a malfunction. |
| 205B29 | The temperature sensor 'AdBlue® tank' has a malfunction. |
| 205B64 | The temperature sensor 'AdBlue® tank' has a malfunction. |
| 205B98 | The temperature sensor 'AdBlue® tank' has a malfunction. |
| 205C16 | The temperature sensor 'AdBlue® tank' has a short circuit to ground. |
| 205C21 | The temperature sensor 'AdBlue® tank' has a short circuit to ground. |
| 205D17 | The temperature sensor 'AdBlue® tank' has a short circuit to positive. The limit value for electrical voltage has been exceeded. |
| 205D22 | The temperature sensor 'AdBlue® tank' has a short circuit to positive. |
| 206200 | The output for the AdBlue® supply has an electrical fault or an open circuit. |
| 206213 | The output for the AdBlue® supply has an electrical fault or an open circuit. |
| 206300 | The output for the AdBlue® supply has a short circuit to ground. |
| 206400 | The output for the AdBlue® supply has a short circuit to positive. |
| 208A13 | The output for the AdBlue® delivery pump has an electrical fault or an open circuit. |
| 208B00 | The output for the AdBlue® delivery pump has a malfunction. |
| 208B21 | The output for the AdBlue® delivery pump has a malfunction. |
| 208B22 | The output for the AdBlue® delivery pump has a malfunction. |
| 208B23 | The output for the AdBlue® delivery pump has a malfunction. |
| 208B24 | The output for the AdBlue® delivery pump has a malfunction. |
| 208B31 | The output for the AdBlue® delivery pump has a malfunction. |
| 208B4B | The output for the AdBlue® delivery pump has a malfunction. |
| 208B77 | The output for the AdBlue® delivery pump has a malfunction. |
| 208B86 | The output for the AdBlue® delivery pump has a malfunction. |
| 208C11 | The output for the AdBlue® delivery pump has a short circuit to ground. |
| 208C21 | The output for the AdBlue® delivery pump has a short circuit to ground. |
| 208D12 | The output for the AdBlue® delivery pump has a short circuit to positive. |
| 208D27 | The output for the AdBlue® delivery pump has a short circuit to positive. |
| 209F00 | The heating of the AdBlue® tank module has a malfunction. |
| 20A000 | Component 'A103/2y1 (AdBlue® switchover valve)' has a malfunction. |
| 20A100 | Component 'A103/2y1 (AdBlue® switchover valve)' has a malfunction. |
| 20A200 | Component 'A103/2y1 (AdBlue® switchover valve)' has a malfunction. |
| 20A300 | Component 'A103/2y1 (AdBlue® switchover valve)' has a malfunction. |
| 20B513 | The output for the heating element of the AdBlue® delivery module has an electrical fault or an open circuit. |
| 20B51B | The output for the heating element of the AdBlue® delivery module has an electrical fault or an open circuit. |
| 20B521 | The output for the heating element of the AdBlue® delivery module has an electrical fault or an open circuit. |
| 20B619 | Component 'A103/2r1 (AdBlue® delivery module heating element)' has a short circuit. |
| 20B61A | The output for the heating element of the AdBlue® delivery module has an electrical fault or an open circuit. |
| 20B61B | The output for the heating element of the AdBlue® delivery module has an electrical fault or an open circuit. |
| 20B621 | The output for the heating element of the AdBlue® delivery module has an electrical fault or an open circuit. |
| 20B622 | The output for the heating element of the AdBlue® delivery module has an electrical fault or an open circuit. |
| 20B711 | The output for the heating element of the AdBlue® delivery module has a short circuit to ground. |
| 20B712 | The output for the heating element of the AdBlue® delivery module has a short circuit to ground. |
| 20B716 | The output for the heating element of the AdBlue® delivery module has a short circuit to ground. |
| 20B717 | The output for the heating element of the AdBlue® delivery module has a short circuit to ground. |
| 20B718 | The output for the heating element of the AdBlue® delivery module has a short circuit to ground. The limit value for current has not been attained. |
| 20B811 | The output for the heating element of the AdBlue® delivery module has a short circuit to positive. |
| 20B812 | The output for the heating element of the AdBlue® delivery module has a short circuit to positive. |
| 20B816 | The output for the heating element of the AdBlue® delivery module has a short circuit to positive. |
| 20B817 | The output for the heating element of the AdBlue® delivery module has a short circuit to positive. |
| 20B819 | The output for the heating element of the AdBlue® delivery module has a short circuit to positive. |
| 20B822 | The output for the heating element of the AdBlue® delivery module has a short circuit to positive. |
| 20B913 | The output for the heating element of the AdBlue® pressure line has an electrical fault or an open circuit. |
| 20B91B | The output for the heating element of the AdBlue® pressure line has an electrical fault or an open circuit. |
| 20B931 | The output for the heating element of the AdBlue® pressure line has an electrical fault or an open circuit. |
| 20BA00 | The output for the heating element of the AdBlue® pressure line has a malfunction. |
| 20BA01 | The output for the heating element of the AdBlue® pressure line has a malfunction. |
| 20BA13 | The output for the heating element of the AdBlue® pressure line has a malfunction. |
| 20BA19 | The output for the heating element of the AdBlue® pressure line has a malfunction. |
| 20BA1A | The output for the heating element of the AdBlue® pressure line has a malfunction. |
| 20BA1B | The output for the heating element of the AdBlue® pressure line has a malfunction. |
| 20BA21 | The output for the heating element of the AdBlue® pressure line has a malfunction. |
| 20BA22 | The output for the heating element of the AdBlue® pressure line has a malfunction. |
| 20BB11 | The output for the heating element of the AdBlue® pressure line has a short circuit to ground. |
| 20BB12 | The output for the heating element of the AdBlue® pressure line has a short circuit to ground. |
| 20BB16 | The output for the heating element of the AdBlue® pressure line has a short circuit to ground. |
| 20BB17 | The output for the heating element of the AdBlue® pressure line has a short circuit to ground. |
| 20BB18 | The output for the heating element of the AdBlue® pressure line has a short circuit to ground. |
| 20BC00 | The output for the heating element of the AdBlue® pressure line has a short circuit to positive. |
| 20BC01 | The output for the heating element of the AdBlue® pressure line has a short circuit to positive. |
| 20BC11 | The output for the heating element of the AdBlue® pressure line has a short circuit to positive. |
| 20BC12 | The output for the heating element of the AdBlue® pressure line has a short circuit to positive. |
| 20BC16 | The output for the heating element of the AdBlue® pressure line has a short circuit to positive. |
| 20BC19 | The output for the heating element of the AdBlue® pressure line has a short circuit to positive. |
| 20BD00 | The output for the heating element of the AdBlue® tank has an electrical fault or an open circuit. |
| 20BD13 | The output for the heating element of the AdBlue® tank has an electrical fault or an open circuit. |
| 20BD1B | The output for the heating element of the AdBlue® tank has an electrical fault or an open circuit. |
| 20BE01 | The output for the heating element of the AdBlue® tank has a malfunction. |
| 20BE13 | The output for the heating element of the AdBlue® tank has a malfunction. |
| 20BE19 | The output for the heating element of the AdBlue® tank has a malfunction. |
| 20BE1A | The output for the heating element of the AdBlue® tank has a malfunction. |
| 20BE1B | The output for the heating element of the AdBlue® tank has a malfunction. |
| 20BE21 | The output for the heating element of the AdBlue® tank has a malfunction. |
| 20BE22 | The output for the heating element of the AdBlue® tank has a malfunction. |
| 20BF12 | The output for the heating element of the AdBlue® tank has a short circuit to ground. |
| 20BF16 | The output for the heating element of the AdBlue® tank has a short circuit to ground. |
| 20BF18 | The output for the heating element of the AdBlue® tank has a short circuit to ground. |
| 20BF21 | The output for the heating element of the AdBlue® tank has a short circuit to ground. |
| 20C011 | The output for the heating element of the AdBlue® tank has a short circuit to positive. |
| 20C012 | The output for the heating element of the AdBlue® tank has a short circuit to positive. |
| 20C017 | The output for the heating element of the AdBlue® tank has a short circuit to positive. |
| 20C019 | The output for the heating element of the AdBlue® tank has a short circuit to positive. |
| 20C022 | The output for the heating element of the AdBlue® tank has a short circuit to positive. |
| 20E821 | The pressure in the AdBlue® system is too low. |
| 20E823 | The pressure in the AdBlue® system is too low. |
| 20E922 | The pressure in the AdBlue® system is too high. |
| 20E924 | The pressure in the AdBlue® system is too high. |
| 20E927 | The pressure in the AdBlue® system is too high. |
| 20EA92 | Relay 'Voltage supply (circuit 30)' of component 'N118/5 (AdBlue® control unit)' switches off too early. |
| 20EB71 | The power supply at the input of the control unit 'combustion engine' has a malfunction. |
| 20F473 | The AdBlue® consumption is too low. |
| 222721 | The ambient pressure sensor has a malfunction. |
| 222722 | The ambient pressure sensor has a malfunction. |
| 222786 | The ambient pressure sensor has a malfunction. |
| 222821 | The ambient pressure sensor has a short circuit to ground. |
| 222922 | The ambient pressure sensor has a short circuit to positive. |
| 242B21 | Temperature sensor 3 'Exhaust system' (cylinder bank 1) has a malfunction. |
| 242B22 | Temperature sensor 3 'Exhaust system' (cylinder bank 1) has a malfunction. |
| 242B86 | Temperature sensor 3 'Exhaust system' (cylinder bank 1) has a malfunction. |
| 242C00 | Temperature sensor 3 'Exhaust system' (cylinder bank 1) has a malfunction. |
| 242D00 | Temperature sensor 3 'Exhaust system' (cylinder bank 1) has a malfunction. |
| 250671 | The power supply at the input of the control unit 'combustion engine' has a malfunction. |
| 250692 | The power supply at the input of the control unit 'combustion engine' has a malfunction. |
| 261000 | The engine off time has an implausible value. |
| 2BA831 | Dosage of the SCR system switched off due to missing input temperature for model (failure temperature before DPF and before SCR) |
| 300000 | Timeout error |
| 300100 | The temperature of component 'Y129 (AdBlue® metering valve)' is outside the permissible range. |
| 300200 | SCRPODUrDosVlvTCoilPlaus: Plausibility of urea dosing valve coil temperature |
| C10000 | Communication with the control unit 'combustion engine' has a malfunction. |
| C10002 | Implausible data were received from control unit 'combustion engine'. |
| C10008 | C10008 |
| C10013 | Implausible data were received from control unit 'combustion engine'. |
| C1001F | Implausible data were received from control unit 'combustion engine'. |
| C10029 | Implausible data were received from control unit 'combustion engine'. |
| C1002F | Implausible data were received from control unit 'combustion engine'. |
| C10031 | Implausible data were received from control unit 'combustion engine'. |
| C10039 | Implausible data were received from control unit 'combustion engine'. |
| C10061 | Implausible data were received from control unit 'combustion engine'. |
| C10062 | Implausible data were received from control unit 'combustion engine'. |
| C10081 | Communication with the control unit 'combustion engine' has a malfunction. Incorrect data were received. |
| C10086 | Implausible data were received from control unit 'combustion engine'. |
| C10087 | Implausible data were received from control unit 'combustion engine'. |
| C1008F | Implausible data were received from control unit 'combustion engine'. |
| C40002 | Implausible data were received from control unit 'combustion engine'. |
| C40004 | Implausible data were received from control unit 'combustion engine'. |
| C40008 | Implausible data were received from control unit 'combustion engine'. |
| C40029 | Implausible data were received from control unit 'combustion engine'. |
| C40081 | Implausible data were received from control unit 'combustion engine'. |
| C40086 | Implausible data were received from control unit 'combustion engine'. |
| C40100 | Implausible data were received from control unit 'combustion engine'. |
| C40102 | Implausible data were received from control unit 'combustion engine'. |
| C40108 | Implausible data were received from control unit 'combustion engine'. |
| C40113 | Implausible data were received from control unit 'combustion engine'. |
| C40129 | Implausible data were received from control unit 'combustion engine'. |
| C4012F | Implausible data were received from control unit 'combustion engine'. |
| C40131 | Implausible data were received from control unit 'combustion engine'. |
| C40151 | Implausible data were received from control unit 'combustion engine'. The component is not programmed. |
| C40161 | Implausible data were received from control unit 'combustion engine'. The signal calculation is faulty. |
| C40162 | Implausible data were received from control unit 'combustion engine'. The signal comparison is faulty. |
| C40164 | Implausible data were received from control unit 'combustion engine'. |
| C40181 | Implausible data were received from control unit 'combustion engine'. |
| C40186 | Implausible data were received from control unit 'combustion engine'. |
| C40187 | Implausible data were received from control unit 'combustion engine'. |
| C4018F | Implausible data were received from control unit 'combustion engine'. |
| C40A29 | Filtered outdoor temperature from the air conditioning control unit |
| C41600 | Implausible data were received from control unit 'Traction system'. |
| C41629 | Implausible data were received from control unit 'Traction system'. There is an invalid signal. |
| C41686 | Implausible data were received from control unit 'Traction system'. There is an incorrect signal. |
| C42308 | Implausible data were received from the instrument cluster. |
| C42309 | Implausible data were received from the instrument cluster. |
| C42329 | Implausible data were received from the instrument cluster. |
| C42429 | Implausible data were received from the air conditioning. |
| C4242A | Implausible data were received from the air conditioning. There is no signal change. |
| C4242B | Implausible data were received from the air conditioning. The electrical lines have a short circuit to each other. |
| C4242C | Implausible data were received from the air conditioning system. An invalid signal is present. |