Home >> Mercedes Benz >> 2017 >> GLE350d >> Repair and Diagnosis (Single Page) >> Accessories & Equipment >> Accessories Control Systems >> Electrical System - Body - 166 Chassis - 1 Of 8 >> Basic Knowledge >> Component Description For Overhead Control Panel Control Unit >> Component Description For Overhead Control Panel Control Unit - GF82.20-P-5216GR
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Component Description For Overhead Control Panel Control Unit - GF82.20-P-5216GR

MODEL 166 up to model year 2016 

Shown on model 166.0 

Fig 1: Overhead Control Panel Control Unit Component Location - Model 166 Up To Model Year 2016
G12081588Courtesy of MERCEDES-BENZ USA

With CODE 882 (Interior monitoring (with ATA [EDW] only)), shown on model 166.0 

G12081589

With CODE 359 (TELEAID emergency call system) or with CODE 348 (Emergency call/assist system), shown on 166.0 

G12081590

Location 

The overhead control panel control unit is located in the front section of the headliner.

Task 

The overhead control panel control unit has the following tasks:

Reading in of sensors and signals 

The input factors are read in via the following connections:

Direct line 

The overhead control panel control unit reads in the signals of the following components via direct lines:

With CODE 882 (Interior monitoring (with ATA [EDW] only)) or with CODE 359 (TELEAID emergency call system) or CODE 348 (Emergency call/assist system):

Roof LIN 

The overhead control panel control unit reads in the requests from the SAM control unit (N10) to switch on the interior lights via the roof LIN.

Evaluation of input factors 

The input factors are evaluated by the microprocessor and the corresponding components are actuated.

Actuation of components 

The actuation of the components takes place via the following connections:

The following components are actuated via direct lines:

Additionally with CODE 882 (Interior monitoring (with ATA [EDW] only)) or with CODE 359 (TELEAID emergency call system) or CODE 348 (Emergency call/assist system):

Additionally in model 166.8 with CODE 876 (Interior lights package):

Roof LIN 

The overhead control panel control unit transmits status information of the switch located on the housing via roof LIN to the SAM control unit.

  Wiring diagram for overhead control panel (OCP) control unit   PE54.21-P-2107-97NAA