Home >> Mercedes Benz >> 2017 >> GLE550e >> Repair and Diagnosis (Single Page) >> Accessories & Equipment >> Anti-Theft Systems >> Central Locking System - 166 Chassis - 1 Of 2 >> Basic Knowledge >> ATA/Tow-Away Protection/Interior Protection Control Unit, Component Description >> ATA/Tow-Away Protection/Interior Protection Control Unit, Component Description - GF80.50-P-4131GR
April 5, 2026: LEMON Manuals is launched! Read the announcement.

ATA/Tow-Away Protection/Interior Protection Control Unit, Component Description - GF80.50-P-4131GR

MODEL 166 up to model year 2016 

with CODE 882 (Interior monitoring (with ATA [EDW] only)) 

Shown on model 166.0 

Fig 1: ATA/Tow-Away Protection/Interior Protection Control Unit Component Location - Model 166 Up To Model Year 2016 With Code 882
G12080314Courtesy of MERCEDES-BENZ USA

Task 

The ATA [EDW]/tow-away protection/interior protection control unit has the following tasks:

Reading in of signals 

The input factors are read in via the following connections:

Alarm system LIN 

The ATA/tow-away protection/interior protection control unit reads in the signals from the alarm siren (H3/1) via the alarm system LIN.

Transmitting signals 

The signals are transmitted by the anti-theft alarm system/emergency call system button group via the interior CAN.

Receiving and transmitting ultrasonic waves 

The ATA [EDW]/tow-away protection/interior protection control unit monitors the vehicle interior for movements by sending and receiving ultrasonic waves.

The anti-theft alarm system/emergency call system button group includes the following components:

Location 

The ATA [EDW]/tow-away protection/interior protection control unit is located on the overhead control panel control unit (N70).

Direct line 

The signals from the following components are read via direct lines:

Interior CAN 

The signals are read in by the anti-theft alarm system/emergency call system button group via the interior CAN.

The functions that use these signals are described in the individual function descriptions (see the appropriate block diagram or function schematic).

Evaluation of input factors 

The input factors that have been read in are evaluated by the integrated microprocessor and the relevant components are then actuated.

Actuation of components 

The anti-theft alarm system/emergency call system button group actuates the alarm siren via the alarm system LIN.

The functions that use these signals are described in the individual function descriptions (see the appropriate block diagram or function schematic).

  Electric wiring diagram for anti-theft alarm system control unit (ATA [EDW])   PE80.50-P-2101-97NAA