Seat Climate Control Timer-Controlled Shutoff, Basic Function - GF91.30-S-1000A
Model All (Light transporter)
Overview
This document contains information on:
- General
- Function
General
The time-controlled shutoff function has the task of deactivating functions after certain time intervals. The function is controlled by the signal acquisition and actuation module.
Function
The signal acquisition and actuation module switches off the following seat climate control functions automatically on a timed basis:
- Seat heater
- Seat ventilation
Timer control is carried out depending on the set stage:
- Heating level/seat ventilation level 3 is active for 8 min. The seat climate control then switches automatically to stage 2.
- Heating level/seat ventilation level 2 is active for 10 min. The seat climate control then switches automatically to stage 1.
- Heating level/seat ventilation level 1 is active for 20 min. The seat climate control then switches off automatically.
The timer control of the three levels can be adjusted using the diagnosis tester.