LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Mercedes Benz >> 2018 >> S450 Base >> Repair and Diagnosis (Single Page) >> Engine Performance >> Engine Control Systems >> Mixture Formation - 222 Chassis (1 Of 3) >> Basic Knowledge >> Alternator Interface Function >> Alternator Interface Function - GF07.10-P-1009MMK
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Alternator Interface Function - GF07.10-P-1009MMK

Engine 276.8 in model 217, 222 

Engine 276.9 in model 222 

Function requirements for the alternator interface, general points 

Alternator interface, general points 

With the alternator interface messages (for example the "Dynamo Field Monitor Signal") are exchanged via the drive LIN (LIN C1) between the alternator (G2) and the ME-SFI [ME] control unit (N3/10) and the control response of the alternator is controlled.

To do this there is delayed adaptation of the charging voltage for a larger change in load of the alternator. The current operating rate of the alternator is transmitted by the dynamo field monitor signal.

The maximum data transmission rate between the ME-SFI [ME] control unit and the LIN control for the alternator is 19.2 kbit/s. The LIN control has no direct outputs. The ME-SFI [ME] control unit reads in the following signals:

Function sequence for alternator interface 

The ME-SFI [ME] control unit regulates the control response of the alternator, for example in order to reduce the charging voltage when idling if the on-board electrical system battery is sufficiently charged.

This reduces the engine load, thus also reducing fuel consumption and reduces exhaust emissions.

The ME-SFI [ME] control unit controls the following functions:

The alternator performs continuous self-diagnosis and transmits the results when requested to the ME-SFI [ME] control unit. This compares the results with other signals (for example, engine rpm, on-board electrical system voltage, time since engine start) and thus detects any alternator faults.

The following faults are identified:

IMPORTANT In order check the charging voltage the on-board electrical system battery is loaded using a battery test device since for a completely charged and under no load on-board electrical system battery, the charging voltage is significantly reduced.

IMPORTANT Circuit 61 signal

Using information received by the ME-SFI [ME] control unit over the alternator interface, the "circuit 61 signal" is simulated in the ME-SFI [ME] control unit and issued over the CAN network (e.g. for the IC).

  Electrical function schematic for alternator interface   PE07.10-P-2709-97SEC
  Overview of system components for gasoline injection and ignition system with direct injection Engine 276.9 in model 222 GF07.70-P-9998MMK 
    Engine 276.8 in model 217, 222 GF07.70-P-9998MMT