Home >> Mercedes Benz >> 2021 >> Metris Van Cargo >> Repair and Diagnosis (Single Page) >> Accessories & Equipment >> Accessories Control Systems >> Electrical System, Equipment & Instruments (03 Of 11) -- 447 Chassis >> Basic Knowledge >> PSM Arithmetic, Example Of PSM Function >> PSM Arithmetic, Example Of PSM Function - GF54.21-S-3055-01TRC
April 5, 2026: LEMON Manuals is launched! Read the announcement.

PSM Arithmetic, Example Of PSM Function - GF54.21-S-3055-01TRC

Model 447 

With Code ED5 (Parameterisable special module) 

Except Code XM7 (MOPF II) 

Speed signal, differentiator/integrator 

Model 448 

With Code ED5 (Parameterisable special module) 

Except Code XM7 (MOPF II) 

Speed signal, differentiator/integrator 

G16501300Courtesy of MERCEDES-BENZ USA

Speed signal function blocks 

The speed signal (interior CAN (CAN B): "VehSpd_Disp") can be output at one of the pulse-width-modulation-compatible outputs.

Formula: Pulse [1/s] = (Speed [km/h] * 4 [pulse/m])/3.6

Value range for speed 4...409.4 km/h
Value range of pulse width modulated signal 0...100 %
Pulse length 200 Hz

4 pulses/m are output. The pulse width is 4 ms.

At 112.5 km/h, the pulse duration is the same as the pulse pause. This 1:1 ratio is maintained up to higher speeds.

In other words, at higher speeds the pulse length and pause length shorten at the same time.

The speed signal is implemented via the blocks of the programmable logic controller (PLC), arithmetic unit and multifunction output blocks. The picture shows the simplified function block operation.

The configuration is available in the tables.

Function description of implementation 

Comparator 2, calculation step 1 (Comp 2): 

Arithmetic block 3, calculation step 2 (Calc 3): 

Arithmetic block 4, calculation step 3 (Calc 4): 

Arithmetic block 5, calculation step 4 (Calc 5): 

PLC G11 threshold switch(S): 

PLC G12 value table 1 (WT1): 

Multifunction output block (MFA 6): 

The cycle duration and pulse duration are output depending on the input signal.

IMPORTANT Signal identification number = Signal ID. The signal IDs are notated in hexadecimal form.

ARITHMETIC UNIT - COMPARATOR 2, CALCULATION STEP 1 (COMP 2), CONFIGURATION

Input Signal name Signal ID Comparison assignment
Compare_2_a Out_AU_Const_3 0x8042 Input a (a) > Input b (b)
Compare_2_b VehSpd_Disp 0x3023  
Compare_2_c VehSpd_Disp 0x3023  
Compare_2_d Const_Bit_0 0x1000  
ARITHMETIC UNIT - ARITHMETIC BLOCK 3, CALCULATION STEP 2 (CALC 3), CONFIGURATION

Input Signal name Signal ID Upper limit value Lower limit value
Calc_3_a Out_AU_Compare_2 0x8025 16 376 0
Calc_3_m1 Out_AU_Const_4 0x8043    
Calc_3_m2 Const_Bit_1 0x1001    
Calc_3_b Const_Bit_0 0x1000    
ARITHMETIC UNIT - ARITHMETIC BLOCK 4, CALCULATION STEP 3 (CALC 4), CONFIGURATION

Input Signal name Signal ID Upper limit value Lower limit value
Calc_4_a Out_AU_Const_5 0x8044 3 600 000 0
Calc_4_m1 Const_Bit_1 0x1001    
Calc_4_m2 Out_AU_Calc_3 0x8002    
Calc_4_b Const_Bit_0 0x1000    
PLC G11 THRESHOLD SWITCH (S), CONFIGURATION

Input F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 F11 F12 F13 F14 F15 F16 Signal name Signal ID Mode Sequential point (1)
SS1_1  0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Out_AU_Calc_4 0x8003 Threshold A  0
  Threshold B  800
  Threshold C  22 727
  Threshold D  65 535
ARITHMETIC UNIT - ARITHMETIC BLOCK 5, CALCULATION STEP 4 (CALC 5), CONFIGURATION

Input Signal name Signal ID Upper limit value Lower limit value
Calc_5_a Out_AU_Calc_4 0x8003 400 0
Calc_5_m1 Const_Bit_1 0x1001    
Calc_5_m2 Out_AU_Const_6 0x8045    
Calc_5_b Const_Bit_0 0x1000    
PLC G12 VALUE TABLE 1 (WT1), CONFIGURATION

Input F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 F11 F12 F13 F14 F15 F16 Signal name Signal ID Value table 1 Default value (signal name) Const_Bit_0 0x1000
WT1_1 (Value 1)  0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Out_G11_SS1_A 0x11D3 - Value 1 (Signal name)  Out_AU_Calc_5 0x8004
WT1_2 (Value 2)  0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Out_G11_SS1_B 0x11D4 - Value 2 (Signal name)  Out_G12_K1_Value 0x308C
WT1_3 (Value 3)  0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Out_G11_SS1_C 0x11D5 - Value 3 (Signal name)  Const_Bit_0 0x1000
WT1_4 (Value 4)  0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Const_Bit_0 0x1000 - Value 4 (signal name)  Const_Bit_0 0x1000
ARITHMETIC UNIT - CONSTANTS BLOCKS, CONFIGURATION

Constants block (KB_1) Arithmetic unit Meaning
Konstante 3 4094 Maximum reception value
Konstante 4 4 Number of pulses per meter
Konstante 5 3 600 000 Speed factor in cycle duration
Konstante 6 2 Pulse duration factor
PLC G12 VALUE TABLE 1 (WT1), CONFIGURATION

Konstantenblock 1 (KB1) Group 12 Meaning
Konstante 1 400 Pulse duration
MULTIFUNCTION OUTPUT BLOCK (MFA6) CONFIGURATION

1 A High Side, PWM F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 F11 F12 F13 F14 F15 F16 Signal name Signal ID Multifunction output block -
Eingang1 (Active)  0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Out_AU_Com-pare_2 0x8025 - Model  Output (1)
Eingang2 (Const/puls)  - - - - - - - - - - - - - - - - Const_Bit_0 0x1000   Reactivation attempts  1
Eingang3 (Cutoff reset)  - - - - - - - - - - - - - - - - Term15_Actv 0x1219   PWM type  Time (1)
Eingang4 (Cycle time)  - - - - - - - - - - - - - - - - Const_Bit_0 0x1000 -
Eingang5 (Pulse time)  - - - - - - - - - - - - - - - - Const_Bit_1 0x1001  
Eingang6 (PWM active)  - - - - - - - - - - - - - - - - Out_AU_Com-pare_2 0x8025  
Eingang7 (PWM period)  - - - - - - - - - - - - - - - - Out_AU_Calc_4 0x8003  
Eingang8 (PWM duty)  - - - - - - - - - - - - - - - - Out_G12_WT1 0x308B