Caravan Control Unit Configuration Of Analog Outputs, Function - GF54.21-D-5021TSA
Model 447
with code JA3 (Intelligent body control.)
with code XM7 (MOPF II)
Model 907, 910
with code JA3 (Intelligent body control.)
General
Analog outputs are used to set voltage values to, e.g. actuate a device that - depending on the voltage applied to its input - executes specific actions.
The MB Advanced Control, control unit (N175) can operate 5 analog outputs.
The MBAC consists of two stages, MBAC Stage I and MBAC Stage II. The MBAC is designed so that the assignment of the I/O interfaces is configurable. The assignment of the I/O interfaces is configured by the bodybuilder manufacturer.
Assignment of I/O interfaces with analog outputs (example)
Each stage has exactly one analog output "AO_Heating_Temperature_Actual_Value".
Each stage has exactly one analog output "AO_Heating_Temperature_Specified_Value".