LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Mercedes Benz >> 2021 >> Metris Van Cargo >> Repair and Diagnosis (Single Page) >> Electrical >> Charging Systems >> Electrical System, Equipment & Instruments (02 Of 11) -- 447 Chassis >> Basic Knowledge >> Onboard Logic Unit (OLU) Digital Inputs, Detailed Information >> Onboard Logic Unit (OLU) Digital Inputs, Detailed Information - GF54.21-S-0033A
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Onboard Logic Unit (OLU) Digital Inputs, Detailed Information - GF54.21-S-0033A

Model 447 

with code JO2 (OLU pre-installation) 

with code JO3 (OLU Connect Unit) 

with code JO4 (OLU Compute Unit) 

with code JO5 (OLU with head unit integration) 

except code XM7 (MOPF II) 

Digital inputs OLU communication module 

The OLU communication module is equipped with the following digital inputs:

Cable-free: 

Cabled: 

Digital inputs OLU central computer 

The OLU central computer has the following digital inputs:

Cable-free: 

Cabled: 

IMPORTANT LTE (Long Term Evolution)

LVDS (Low voltage differential signal)

USB (Universal Serial Bus)

Internal OLU communication (OLU communication module and OLU central computer) 

Both the OLU communication module and OLU central computer units communicate with each other within the OLU via "Fast Ethernet" as per "1000Base-T1 BroadR-Reach".

IMPORTANT Vehicles with code JO3 (OLU connect unit) are only equipped with the OLU communication module component.

Vehicles with code JO4 (OLU compute unit) or with code JO5 (OLU with head unit integration) are equipped with both components (OLU communication module and OLU central computer).