Caravan Control Unit Configuration Of Digital Inputs, Function - GF54.21-D-5024TSA
Model 447
with code JA3 (Intelligent body control.)
with code XM7 (MOPF II)
Model 907, 910
with code JA3 (Intelligent body control.)
General
The MB Advanced Control, control unit (N175) consists of two stages, MBAC Stage I and MBAC Stage II. The MBAC is designed so that the assignment of the I/O interfaces is configurable. The assignment of the I/O interfaces is configured by the bodybuilder manufacturer.
The MBAC can operate up to 29 digital inputs. Of these, 16 are specific digital inputs with wake-up capability, and 13 are specific digital inputs with no wake-up capability. In addition to the 29 digital inputs, there is another input capable of wake-up for reading in the Bluetooth® pairing pushbutton switch.
Assignment of I/O interfaces with digital inputs (example)
MBAC Stage I has exactly one digital input "DI_Pairing-Reset_Pushbutton_Switch".
MBAC Stage II has exactly one digital input "DI_Wake-up_Pushbutton_Switch".
Each stage has exactly one digital input "DI_Heizung_Ausgleichsbehaelter1_Pushbutton_Switch".
Each stage has exactly one digital input "DI_Heizung_Ausgleichsbehaelter2_Pushbutton_Switch".
Each stage has_reached exactly one digital input "DI_Warmwasser_70C".
Each stage has exactly one digital input "DI_Batteriemanagement_12V_Charger".
Each stage has exactly one digital input "DI_Lichtkreis_Weiss1_Pushbutton_Switch".
Each stage has exactly one digital input "DI_Lichtkreis_Weiss2_Pushbutton_Switch".
Each stage has exactly one digital input "DI_Lichtkreis_Weiss3_Pushbutton_Switch".
Each stage has exactly one digital input "DI_Light_Circuit_RGB_Pushbutton_Switch".
Each stage has exactly one digital input "DI_Battery_Management_Solar_Equipment".
Each stage has exactly one digital input "DI_Battery_Management_Alternator".
Each stage has exactly one digital input "DI_Roof_Ventilation_Flap_Limit_Switch_Opened".
Each stage has exactly one digital input "DI_Roof_Ventilation_Flap_Limit_Switch_Closed".
Each stage has exactly one digital input "DI_Roof_Ventilation_Flap_Pushbutton_Switch_Open".
Each stage has exactly one digital input "DI_Roof_Ventilation_Flap_Pushbutton_Switch_Close".
Each stage has exactly one digital input DI_Popup_Roof_Limit_Switch_Retracted".
Each stage has exactly one digital input "DI_Rollo1_Limit_Switch_Retracted".
Each stage has exactly one digital input "DI_Rollo1_Limit_Switch_Extended".
Each stage has exactly one digital input "DI_Rollo2_Limit_Switch_Retracted".
Each stage has exactly one digital input "DI_Rollo2_Limit_Switch_Extended".
Each stage has exactly one digital input "DI_Awning_Limit_Switch_Retracted".
Each stage has exactly one digital input "DI_Awning_Limit_Switch_Extended".
| Caravan control unit configuration of analog outputs, function | GF54.21-D-5021TSA | ||
| Caravan control unit configuration of analog inputs, function | GF54.21-D-5022TSA | ||
| Caravan control unit configuration of digital outputs, function | GF54.21-D-5023TSA | ||
| Caravan control unit parameters of analog inputs, function | GF54.21-D-5025TSA | ||
| Caravan control unit parameters of analog outputs, function | GF54.21-D-5026TSA | ||
| Caravan control unit parameters of digital inputs, function | GF54.21-D-5027TSA | ||
| Caravan control unit parameters of digital outputs, function | GF54.21-D-5028TSA | ||
| Overview of system components of caravan control unit | Model 907, 910 | GF54.21-D-9992TSA | |
| Overview of system components of caravan control unit | Model 447 | GF54.21-S-9992TMA |