Caravan Control Unit Parameters Of Digital Outputs, Function - GF54.21-D-5028TSA

Model 447 

with code JA3 (Intelligent body control.) 

with code XM7 (MOPF II) 

Model 907, 910 

with code JA3 (Intelligent body control.) 

General 

IMPORTANT Parameterizable special module (PSM)

Pulse width modulation (PWM)

The digital outputs are used to set digital signals (0 or 1), and they can be set by the integrated software. The functionality of the digital outputs is provided by the driver modules TLE94110EL.

The MB Advanced Control, control unit (N175) can operate 29 digital outputs.

Along with the 29 digital outputs, a further output exists for the PSM wake-up signal.

The MBAC can operate up to 14 PWM outputs. PWM outputs are used, e.g. to dim a light or to control the speed of simple motors.

Parameters for digital outputs 

The digital outputs can provide a rated current of 200 mA and 12 V (High-Side).

Parameters for PSM wake-up signal 

The digital output for the PSM wake-up signal has a maximum output resistance of 1 kOhm.

The digital output for the PSM wake-up signal has a maximum output current of 30 mA.

The digital output for the PSM wake-up signal can switch 12 V (High-Side).

Parameters for PWM outputs 

The PWM outputs switch to the high side (terminal 30).

All PWM outputs together provide a maximum output of 200 watts.

The frequency of the PWM outputs is 200 Hz with a tolerance of ±10 %.

The "duty cycle" for the PWM outputs can be changed in steps of 0.1 % with a tolerance of ±5 %.

  Caravan control unit configuration of analog outputs, function   GF54.21-D-5021TSA 
  Caravan control unit configuration of analog inputs, function   GF54.21-D-5022TSA 
  Caravan control unit configuration of digital outputs, function   GF54.21-D-5023TSA 
  Caravan control unit configuration of digital inputs, function   GF54.21-D-5024TSA 
  Caravan control unit parameters of analog inputs, function   GF54.21-D-5025TSA 
  Caravan control unit parameters of analog outputs, function   GF54.21-D-5026TSA 
  Caravan control unit parameters of digital inputs, function   GF54.21-D-5027TSA 
  Overview of system components of caravan control unit Model 907, 910 GF54.21-D-9992TSA
  Overview of system components of caravan control unit Model 447 GF54.21-S-9992TMA