Caravan Control Unit, Pin Assignment - GF54.21-D-5010-02TSD
Model 447
with code JA3 (Intelligent body control.)
with code XM7 (MOPF II)
Vehicle plug 3
Model 907, 910
with code JA3 (Intelligent body control.)
Vehicle plug 3
Assignment of vehicle plug 3
The vehicle plug 3 of the control unit for MB Advanced Control (N175) has 54 pins. The assignment and current values for each individual pin are listed in the following table.
Pulse width modulation (PWM)
| Pin | Use | Channel | Rated current strength in A | ||
|---|---|---|---|---|---|
| 1 | Output, PWM | 0 | 2 | ||
| 2 | Output, PWM | 1 | 2 | ||
| 3 | Digital input (1) | 0 | 0.01 | ||
| 4 | Output, PWM | 2 | 2 | ||
| 5 | Digital input (1) | 1 | 0.01 | ||
| 6 | Output, PWM | 3 | 2 | ||
| 7 | Digital input (1) | 2 | 0.01 | ||
| 8 | Output, PWM | 4 | 2 | ||
| 9 | Digital input (1) | 3 | 0.01 | ||
| 10 | Output, PWM | 5 | 2 | ||
| 11 | Analog output | 0 | 0.002 | ||
| 12 | Digital input (1) | 4 | 0.01 | ||
| 13 | Digital input (1) | 5 | 0.01 | ||
| 14 | Digital input (1) | 11 | 0.01 | ||
| 15 | Digital input (1) | 12 | 0.01 | ||
| 16 | Digital input (1) | 16 | 0.01 | ||
| 17 | Digital input (1) | 17 | 0.01 | ||
| 18 | Digital input (1) | 8 | 0.01 | ||
| 19 | Digital input (1) | 9 | 0.01 | ||
| 20 | Digital input (1) | 10 | 0.01 | ||
| 21 | Analog output | 1 | 0.002 | ||
| 22 | Analog output | 2 | 0.002 | ||
| 23 | Digital input (1) | 13 | 0.01 | ||
| 24 | Digital input (1) | 14 | 0.01 | ||
| 25 | Digital input (1) | 15 | 0.01 | ||
| 26 | Digital input | 16 | 0.01 | ||
| 27 | Digital input | 17 | 0.01 | ||
| 28 | Digital input | 18 | 0.01 | ||
| 29 | Digital input | 19 | 0.01 | ||
| 30 | Digital input | 20 | 0.01 | ||
| 31 | Analog output | 3 | 0.002 | ||
| 32 | Analog output | 4 | 0.002 | ||
| 33 | Digital input | 21 | 0.01 | ||
| 34 | Digital input | 22 | 0.01 | ||
| 35 | Digital input | 23 | 0.01 | ||
| 36 | Digital input | 24 | 0.01 | ||
| 37 | Digital input | 25 | 0.01 | ||
| 38 | Digital input | 26 | 0.01 | ||
| 39 | Digital input | 27 | 0.01 | ||
| 40 | Digital input | 28 | 0.01 | ||
| 41 | Digital output | 25 | 0.2 | ||
| 42 | Digital output | 26 | 0.2 | ||
| 43 | Digital output | 27 | 0.2 | ||
| 44 | Digital output | 28 | 0.2 | ||
| 45 | Coding for I/O extension bit 0 | - | 0.01 | ||
| 46 | Coding for I/O extension bit 1 | - | 0.01 | ||
| 47 | Ground connection for analog input | - | - | ||
| 48 | Ground connection for analog output | - | - | ||
| 49 | Analog input | 11 | 0.002 | ||
| 50 | Analog input | 12 | 0.002 | ||
| 51 | Analog input | 13 | 0.002 | ||
| 52 | Analog input | 14 | 0.002 | ||
| 53 | Analog input | 15 | 0.002 | ||