Home >> Mercedes Benz >> 2025 >> eSprinter Base, _NA_ >> Repair and Diagnosis (Single Page) >> TMC Recommended Practices >> Onboard Vehicle Electronics >> RP 1210D - Windows (TM) Communication API >> RP 1210D - Windows(TM) Communication API >> RP1210_SENDCOMMAND () >> Values For The NCOMMANDNUMBER Parameter
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Values For The NCOMMANDNUMBER Parameter

TMC has reserved some values for the nCommandNumber  parameter to support functionality considered required functionality. This section defines, in detail, the structure and constitution of these commands. The table below summarizes the send commands defined in this RP.

Command Mnemonic (Defined in API Header File) Value
Reset Device RP1210_Rese_ Device 0
Set All Filter States to Pass RP1210_Set_All_Filters_States_to_Pass 3
Set Message Filtering for J1939 RP1210_Set_Message_Filtering_For_Jl9 3 9 4
Set Message Filtering for CAN RP1210_Set_Message_Filtering_For_CAN 5
Set Message Filtering for J1708 RP1210_Set_Message_Filtering_For_Jl7 0 8 7
Set Message Filtering for J1850 RP1210_Set_Message_Filtering_For_Jl8 5 0 8
Set Message Filtering for ISO15765 RP1210_Set_Message_Filtering_For_ISO15765 9
Generic Driver Command RP1210_Generic_Driver_Command 14
Set J1708 Mode RP1210_Set_J170 8_Mode 15
Set Echo Transmitted Messages RP1210_Echo_Transmitted_Messages 16
Set All Filter States to Discard RP1210_Set_All_Filters_States_to_Discard 17
Set Message Receive RP1210_Set_Message_Receive 18
Protect J1939 Address RP1210_Protect_J1939_Address 19
Set Broadcast List for J1708 RP1210_Set_Broadcast_For_J1708 20
Set Broadcast List for CAN RP1210_Set_Broadcast_For_CAN 21
Set Broadcast List for J1939 RP1210_Set_Broadcast_For _1939 22
Set Broadcast List for J1850 RP1210_Set_Broadcas_ For_J1850 23
Set J1708 Filter Type RP1210_Set_J1708_Filter_Type 24
Set J1939 Filter Type RP1210_Set_J1939_Filter_Type 25
Set CAN Filter Type RP1210_Set_CAN_Filter_Type 26
Set J1939 Broadcast Interpacket Timing RP1210_Set_J1939_Interpacket_Time 27
Set Max Error Message Return Size RP1210_SetMaxErrorMsgSize 28
Disallow Further Client Connections RP1210_Disallow_Further_Connections 29
Set J1850 Filter Type RP1210_Set_Jl850_Filter_Type 30
Release a J1939 Address RP1210_Release_J1939_Address 31
Set ISO15765 Filter Type RP1210_Set_ISO15765_Filter_Type 32
Set Broadcast List for ISO15765 RP1210_Set_Broadcast_For_ISO15765 33
Set ISO15765 Flow Control RP1210_Set_ISO15765_Flow_Control 34
Clear ISO15765 Flow Control RP1210_Clear_ISO15765_Flow_Control 35
Set J1939 Baud Rate RP1210_Set_J1939_Baud 3 7
Set ISO15765 Baud Rate RP1210_Set_ISO15765_Baud 38
Flush the Send/Receive Buffers RP1210_Flush_Tx_Rx_Buffers 39
Intentionally Skipped Previously_used_and_antiquated 40
Set Broadcast List for ISO14230 RP1210_Set_Broadcast_For_ISO14230 41
Set Broadcast List for ISO9141 RP1210_Set_Broadcast_For_ISO9141 42
What Speed Did the VDA Connect? RP1210_Get_Protocol_Connection_Speed 45
Set ISO9141/ISO14230 Mode RP1210_Set_ISO914ISO14230_Mode 46
Set CAN Baud Rate RP1210_Set_CAN_Baud 47
Is the VDA operating in a wireless mode? RP1210_Get_Wireless_State 48
Set Blocking Timeout RP1210_Set_BlockTimeout 215
Set J1708 Baud Rate RP1210_Set_J1708_Baud 305
Set J1850 Baud Rate RP1210_Set_J1850_Baud 306