October 30: LEMON manuals on a temporary server, it is slow and having issues, download the manuals you need! Later in November we will switch back to the fast server.
Ground Circuit Continuity Check
- Insert a small straight pin in control module Black wire. DO NOT
allow straight pin to contact electrical ground. Attach negative voltmeter lead to distributor base and positive lead to straight pin. Turn ignition switch to "RUN" position. Measure voltage at Black wire. Turn ignition to "OFF" position and remove straight pin.
- If voltage reading was greater than .5 volt, proceed to DISTRIBUTOR GROUND CIRCUIT CONTINUITY CHECK. If voltage was .5 volt or less, replace control module.