61 13 ... Crimping Micro Quadlock System contacts (MQS)

WARNING: This page is about a different car, the 2003 BMW Z8, 2002 BMW Z8, 2001 BMW Z8, and 2000 BMW Z8. However, it is still accessible from the selected car via links, so may be relevant.

Special tools required: 

To crimp MQS contacts, use pliers 61 4 321 (1) in conjunction with crimping head 61 4 324 (2) from crimping set 61 4 320.

Fig 1: View Of Pliers
G03207248Courtesy of BMW OF NORTH AMERICA, INC.
NOTE: Pliers (1) open automatically as far as they will go when handles are pressed together.

Open pliers (1).

Fig 2: Inserting MQS Contact In Contact Carrier
G03207249Courtesy of BMW OF NORTH AMERICA, INC.

Fold up contact carrier (2).

Insert MQS contact (3) in contact carrier (2).

Fold back contact carrier (2).

NOTE: Follow procedure for cutting and stripping insulation from cables.

Close pliers (1) one notch.

Insert stripped cable (2).

Close pliers (1) fully.

Fig 3: Inserting Stripped Cable
G03207250Courtesy of BMW OF NORTH AMERICA, INC.

Open pliers (1).

Open contact carrier (2) gently and carefully remove MQS contact.

Fig 4: Removing MQS Contact
G03207251Courtesy of BMW OF NORTH AMERICA, INC.
NOTE: Check contact for correct crimping.