61 13... Crimping Micro Quadlock System contacts (MQS)

WARNING: This page is about a different car, the 2006 BMW X3, 2005 BMW X3, and 2004 BMW X3. However, it is still accessible from the selected car via links, so may be relevant.

Special tools required: 

To crimp MQS contacts, use pliers 61 4 321 (1) in conjunction with crimping head 61 4 324 (2) from crimping set 61 4 320.

Fig 1: Identifying Pliers With Crimping Head
G03311906Courtesy of BMW OF NORTH AMERICA, INC.
NOTE: Pliers (1) open automatically as far as they will go when handles are pressed together.

Open pliers (1).

Fig 2: Assembling Special Tools
G03311907Courtesy of BMW OF NORTH AMERICA, INC.

Fold up contact carrier (2).

Insert MQS contact (3) in contact carrier (2).

Fold back contact carrier (2).

NOTE: Follow procedure for cutting and stripping insulation from cables.

Close pliers (1) one notch.

Fig 3: Inserting Stripped Cable
G03311908Courtesy of BMW OF NORTH AMERICA, INC.

Insert stripped cable (2).

Close pliers (1) fully.

Open pliers (1).

Fig 4: Removing MQS Contact
G03311909Courtesy of BMW OF NORTH AMERICA, INC.

Open contact carrier (2) gently and carefully remove MQS contact.

NOTE: Check contact for correct crimping.