Home >> Mini >> 2013 >> Cooper Base, 2D Convertible, Automatic Trans >> Repair and Diagnosis >> External Pages >> Different car >> Section 396 (General Electrical System - Repair) >> Plug Connection Terminal >> 61 13... Opening plug housings and removing contacts of different plug systems >> 61 13... Socket housing 42-, 43-pin, Hybrid System MQS/MPQ
April 5, 2026: LEMON Manuals is launched! Read the announcement.

61 13... Socket housing 42-, 43-pin, Hybrid System MQS/MPQ

WARNING: This page does not describe the selected car, but rather 17 other vehicles, including the 2010 BMW M5, 2009 BMW M5, 2008 BMW M5, 2007 BMW M5, and 2007 BMW 530xi. However, it is still accessible from the selected car via links, so may be relevant.

Manufactured by AMP:  The following contact types without strand sealing can be fitted in the socket housings:

Open secondary locks (1) on socket housing.

Press back retaining hook of MQS contacts (2) with special tool 61 1 134 and pull out cable with contact.

Press back retaining hook of MPQ contacts (3) with screwdriver or similar tool and pull out cable with contact.

Fig 1: Pressing MQS Contacts Back Retaining Hook Using Special Tool (61 1 134)
G08573849Courtesy of BMW OF NORTH AMERICA, INC.

Installation: 

Bend open retaining hook of contacts gently before inserting into plug housing.

To install contacts, observe cavity numbers on reverse side of socket housing.

Fig 2: Identifying Socket Housing
G08573850Courtesy of BMW OF NORTH AMERICA, INC.